2 Multi-State Lamp
9-20
WindO/I-NV4 User’s Manual
Example 2:
Bit Number
is selected. The bits of trigger device address D0 and the OFF state are
allocated to the following pictures.
Switches the picture to display according to the status of the bits.
Value:
Switches the drawing object displayed, according to the value of the device address.
Example 3: Value is selected. The value assigned to the trigger device address D0 are allocated to the
following pictures and the OFF state is
None
.
Switches the picture to display according to the value of the device address.
Example 4: Value is selected. The values assigned in trigger device address D0 and the OFF state are
allocated to the following pictures.
Switches the picture to display according to the value of the device address.
bit15
bit0
bit3
Value of
Trigger Device Address D0
Picture
State:
0
State:
1
State:
2
OFF
OFF
Display picture
for bit 0
Display picture
for bit 1
Display picture
for bit 2
Display picture
for OFF state
Display picture
for bit 1
Display picture
for bit 2
0001
0010
0100
1000
1110
1100
State:
0
State:
1
State:
1
State:
2
State:
2
Picture to display
Bit state of
Trigger Device Address D0
Action
I f m u l t i p l e b i t s a r e 1 ,
display the picture for the
lowest order bit.
If all bits in the device address are 0 or if
a bit with no associated picture becomes
1, display the picture for OFF state.
0
1
2
Value of
Trigger Device Address D0
Picture
State:
2
State:
1
State:
0
(None)
OFF
Display picture for 0 Display picture for 1 Display picture for 2
No picture
0
1
2
3
State:
0
State:
1
State:
2
Picture to display
Value of
Trigger Device Address D0
Action
If the value of device
address has no picture
associated with it, display
nothing.
OFF
0
1
2
Value of
Trigger Device Address D0
Picture
State:
2
State:
1
State:
0
OFF
Display picture
for 0
Display picture
for 1
Display picture
for 2
Display picture
for OFF state
0
1
2
3
State:
0
State:
1
State:
2
Picture to display
Value of
Trigger Device Address D0
Action
If the value of device
address has no picture
associated with it, display
the picture for OFF state.
Summary of Contents for MICRO/I HG4G-CJT22 F-B Series
Page 1: ...B 1701 11 User s Manual ...
Page 26: ...Preface 25 WindO I NV4 User s Manual ...
Page 106: ...5 WindO I NV4 Common Operations and Settings 2 74 WindO I NV4 User s Manual ...
Page 254: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual ...
Page 362: ...5 Screen Restrictions 5 28 WindO I NV4 User s Manual ...
Page 402: ...3 Text 7 30 WindO I NV4 User s Manual ...
Page 574: ...9 Potentiometer 8 172 WindO I NV4 User s Manual ...
Page 1052: ...4 Using the Data 15 22 WindO I NV4 User s Manual ...
Page 1170: ...6 Important Notes 20 60 WindO I NV4 User s Manual ...
Page 1200: ...5 Restrictions 22 18 WindO I NV4 User s Manual ...
Page 1260: ...5 Editing User Accounts on the MICRO I 23 60 WindO I NV4 User s Manual ...
Page 1322: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual ...
Page 1414: ...4 E mail Function 28 66 WindO I NV4 User s Manual ...
Page 1554: ...3 Settings 34 14 WindO I NV4 User s Manual ...
Page 1642: ...2 Handling Problems 36 6 WindO I NV4 User s Manual ...
Page 1652: ...5 Text Alignment A 10 WindO I NV4 User s Manual ...
Page 1664: ...Index 12 WindO I NV4 User s Manual ...