3 Recipe Settings Dialog Box
18-8
WindO/I-NV4 User’s Manual
This section describes the items and buttons on the
Recipe Settings
dialog box and the
Individual Settings
dialog
box.
3.1 Recipe Settings Dialog Box
Use the
Recipe Settings
dialog box to collectively manage the save destination of data for recipes, the device
addresses for writing recipe values and reading values of device addresses, and those execution conditions.
■
Number of Blocks
The operation using the data for the recipe is configured in blocks (0 to 64). 1 channel is used for 1 item of data for
the recipe. 1 block is 16 channels.
The maximum number of blocks that can be configured is 64 blocks. The maximum number of device addresses that
can be configured for 1 channel is 8192 devices.
■
Settings
Edits the recipe settings for each channel.
3
Recipe Settings Dialog Box
HG3G
HG2G-5F
HG5G-V HG4G-V
HG3G-V
HG2G-V
HG2G-5T
HG4G
HG1G HG1P
No.:
Displayed as (Block No.)-(Channel No.). Double clicking the cell displays the
Individual
Settings
dialog box. For details, refer to “3.2 Individual Settings Dialog Box” on page 18-10.
Access to:
Shows the save destination for the data for the recipe. Double clicking the cell switches between
Internal Memory
and
External Memory Device
.
Trigger Setting:
Shows the operation using the data for the recipe. When
External Memory Device
is selected
for
Access to
, double clicking the cell switches between
Write-only
,
Read/Write
, and
Read-
only
. Shows
Write-only
when
Internal Memory
is selected for
Access to
.
Read Trigger:
Shows the device address that triggers saving the recipe file. Double clicking the cell displays
the Tag Editor. For the device address configuration procedure, refer to Chapter 2 “5.1 Device
Address Settings” on page 2-68.
This option can only be configured when
Read/Write
or
Read-only
is selected under
Trigger
Setting
.
Write Trigger:
Shows the device address that triggers writing recipe values to device addresses. Double
clicking the cell displays the Tag Editor. For the device address configuration procedure, refer to
Chapter 2 “5.1 Device Address Settings” on page 2-68.
This option can only be configured when
Read/Write
or
Write-only
is selected under
Trigger Setting
.
Recipe function:
Shows whether or not to use the Recipe function. Double clicking the cell switches between
Enable
and
Disable
.
Summary of Contents for MICRO/I HG4G-CJT22 F-B Series
Page 1: ...B 1701 11 User s Manual ...
Page 26: ...Preface 25 WindO I NV4 User s Manual ...
Page 106: ...5 WindO I NV4 Common Operations and Settings 2 74 WindO I NV4 User s Manual ...
Page 254: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual ...
Page 362: ...5 Screen Restrictions 5 28 WindO I NV4 User s Manual ...
Page 402: ...3 Text 7 30 WindO I NV4 User s Manual ...
Page 574: ...9 Potentiometer 8 172 WindO I NV4 User s Manual ...
Page 1052: ...4 Using the Data 15 22 WindO I NV4 User s Manual ...
Page 1170: ...6 Important Notes 20 60 WindO I NV4 User s Manual ...
Page 1200: ...5 Restrictions 22 18 WindO I NV4 User s Manual ...
Page 1260: ...5 Editing User Accounts on the MICRO I 23 60 WindO I NV4 User s Manual ...
Page 1322: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual ...
Page 1414: ...4 E mail Function 28 66 WindO I NV4 User s Manual ...
Page 1554: ...3 Settings 34 14 WindO I NV4 User s Manual ...
Page 1642: ...2 Handling Problems 36 6 WindO I NV4 User s Manual ...
Page 1652: ...5 Text Alignment A 10 WindO I NV4 User s Manual ...
Page 1664: ...Index 12 WindO I NV4 User s Manual ...