WindO/I-NV4 User’s Manual
3-83
5 User Communication
3
Communic
ation
Receive command: Command Settings dialog box settings
Operation for receive command
1
Change the trigger condition LM202 from 0 to 1 to be ready for receiving user communication.
2
Data is transmitted from the external device and the transmitted data is received and processed.
The receive data is as follows.
• The receive data is compared with the character data, and the value of the matching Index No. (10 (Dec)) is stored
in Index Device Address LDR230.
• The 2 bytes (specified with
Skip
) of the receive command data 43h and 44h are ignored.
• Since the Reference Device Address LDR 230 of
Device Address
of the receive command data is 10 (Dec), the
data is stored in the device address LDR250 and LDR251, which is offset by +10.
•
[STX] ABCD1234
is calculated with
BCC
of receive command data and compared with 3032h.
- When Calculation Start Position is 1 and Calculation End Position is 0: Calculates the range
STX ABCD1234
.
Item
Setting
Type
RXD
Trigger Condition
While ON, Device Address: LM202
Completed Device Address
LM203
Not Clear Completed Device
Address automatically
No
Status Device Address
LDR260
Receiving Time Out
0 (No Receive Time Out)
Comment
RXD command
Command
Data Settings dialog box
settings
Constant
(Hexadecimal)
'02'
Registering
Constant
(Character)
10: "AB", 20: "CD", Index Device Address: LDR230
Skip
2 bytes
Device Address
Conversion Type: No conversion, from Upper byte,
Number of bytes: 2, Words: 2
Device Address: LDR240, Reference Device Address: LDR230
BCC
Calculation Start Position: 1 Calculation End Position: 0, XOR
Hexadecimal to ASCII, 2 bytes
Constant
(Hexadecimal)
'0D''0A'
3
(33h)
4
(34h)
1
(31h)
STX
(02h)
2
(32h)
A
(41h)
B
(42h)
C
(43h)
D
(44h)
Skip
CR
(0Dh)
LF
(0Ah)
0
(30h)
2
(32h)
BCC
Constant
(Hexadecimal)
Device Address
Constant
(Hexadecimal)
Command settings:
Registering
Constant (Character)
Receive data:
Received data
Compare
A
(41h)
B
(42h)
Order of reception
10
LDR230:
Value of the Index Device Address
AB
10:
CD
20:
Data
Index No.
Number of
Registering
Constants: 2
(DEC)
0000h
LDR240:
0000h
LDR241:
3132h
LDR250:
Value of Device Address
LDR230=10
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
Calculation Start Position:
(5)
(4)
(3)
(8)
(7)
(6)
(2)
(1)
(0)
Calculation End Position:
3
(33h)
4
(34h)
1
(31h)
STX
(02h)
2
(32h)
A
(41h)
B
(42h)
C
(43h)
D
(44h)
CR
(0Dh)
LF
(0Ah)
0
(30h)
2
(32h)
Data used for BCC calculation
Summary of Contents for MICRO/I HG4G-CJT22 F-B Series
Page 1: ...B 1701 11 User s Manual ...
Page 26: ...Preface 25 WindO I NV4 User s Manual ...
Page 106: ...5 WindO I NV4 Common Operations and Settings 2 74 WindO I NV4 User s Manual ...
Page 254: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual ...
Page 362: ...5 Screen Restrictions 5 28 WindO I NV4 User s Manual ...
Page 402: ...3 Text 7 30 WindO I NV4 User s Manual ...
Page 574: ...9 Potentiometer 8 172 WindO I NV4 User s Manual ...
Page 1052: ...4 Using the Data 15 22 WindO I NV4 User s Manual ...
Page 1170: ...6 Important Notes 20 60 WindO I NV4 User s Manual ...
Page 1200: ...5 Restrictions 22 18 WindO I NV4 User s Manual ...
Page 1260: ...5 Editing User Accounts on the MICRO I 23 60 WindO I NV4 User s Manual ...
Page 1322: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual ...
Page 1414: ...4 E mail Function 28 66 WindO I NV4 User s Manual ...
Page 1554: ...3 Settings 34 14 WindO I NV4 User s Manual ...
Page 1642: ...2 Handling Problems 36 6 WindO I NV4 User s Manual ...
Page 1652: ...5 Text Alignment A 10 WindO I NV4 User s Manual ...
Page 1664: ...Index 12 WindO I NV4 User s Manual ...