S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
15-7
Cisco MDS 9000 Family CLI Configuration Guide
OL-16184-01, Cisco MDS SAN-OS Release 3.x
Chapter 15 Configuring Trunking
Default Settings
Hardware is Fibre Channel
Port WWN is 20:0d:00:05:30:00:58:1e
Peer port WWN is 20:0d:00:05:30:00:59:1e
Admin port mode is auto, trunk mode is on
Port mode is TE
Port vsan is 1
Speed is 2 Gbps
Receive B2B Credit is 255
Beacon is turned off
Trunk vsans (admin allowed and active) (1)
Trunk vsans (up) (1)
Trunk vsans (isolated) ()
Trunk vsans (initializing) ()
5 minutes input rate 0 bits/sec, 0 bytes/sec, 0 frames/sec
5 minutes output rate 0 bits/sec, 0 bytes/sec, 0 frames/sec
233996 frames input, 14154208 bytes, 0 discards
0 CRC, 0 unknown class
0 too long, 0 too short
236 frames output, 13818044 bytes, 0 discards
11 input OLS, 12 LRR, 10 NOS, 28 loop inits
34 output OLS, 19 LRR, 17 NOS, 12 loop inits
Example 15-2 Displays the Trunking Protocol
switch#
show trunk protocol
Trunk protocol is enabled
Example 15-3 Displays Per VSAN Information on Trunk Ports
switch#
show interface trunk vsan 1-1000
fc3/1 is not trunking
...
fc3/7 is trunking
Vsan 1000 is down (Isolation due to vsan not configured on peer)
...
fc3/10 is trunking
Vsan 1 is up, FCID is 0x760001
Vsan 2 is up, FCID is 0x6f0001
fc3/11 is trunking
Belongs to port-channel 6
Vsan 1 is up, FCID is 0xef0000
Vsan 2 is up, FCID is 0xef0000
...
port-channel 6 is trunking
Vsan 1 is up, FCID is 0xef0000
Vsan 2 is up, FCID is 0xef0000
Default Settings
Table 15-2
lists the default settings for trunking parameters.