S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
14-37
Cisco MDS 9000 Family CLI Configuration Guide
OL-16184-01, Cisco MDS SAN-OS Release 3.x
Chapter 14 Configuring Generation 2 Switches and Modules
Example Configurations
switch#
Configuring a 48-port 4-Gbps Fibre Channel Switching Module Example
This section describes how to configure the example shown in
Figure 14-4 on page 14-11
.
Step 1
Select interfaces fc 4/11 through fc 4/12.
switch#
config t
switch(config)#
interface fc 4/11 - 12
Step 2
Disable the interfaces and take them out of service.
switch(config-if)#
shutdown
switch(config-if)#
out-of-service
Step 3
Return to configuration mode.
switch(config-if)#
exit
switch#
Step 4
Select the interfaces fc 4/1 through fc 4/6.
switch#
config t
switch(config)#
interface fc 4/1 - 6
Step 5
Configure the port speed, rate mode, and port mode on the interfaces.
switch(config-if)#
switchport speed auto max 2000
switch(config-if)#
switchport rate-mode dedicated
switch(config-if)#
switchport mode e
Step 6
Enable the interfaces and return to configuration mode.
switch(config-if)#
no shutdown
switch(config-if)#
exit
switch#
Step 7
Select the interfaces fc 4/7 through fc 4/10.
switch#
config t
switch(config)#
interface fc 4/7 - 10
Step 8
Configure the port speed, rate mode, and port mode on the interfaces.
switch(config-if)#
switchport speed 1000
switch(config-if)#
switchport rate-mode shared
switch(config-if)#
switchport mode f
Step 9
Enable the interfaces and return to configuration mode.
switch(config-if)#
no shutdown
switch(config-if)#
exit