Optimizing Measurements
Reducing Mismatch Errors
Source match errors in transmission measurements can be reduced by
performing an enhanced response calibration. (See Chapter 6.) Load
match errors can be reduced by using an attenuator on the analyzer’s
TRANSMISSION RF IN port.
N O T E
Always use high quality attenuators. Six to tan of attenuation should be sufficient to significantly
reduce mismatch errors.
When you want to measure reflection and transmission simultaneously, or
without changing the test setup, perform both a reflection calibration and an
enhanced response calibration using the exact frequency parameters that you
will be using for the measurement, and put a 6 to 10
pad directly on the
output of the DUT.
N O T E
Using an attenuator on the output of the DUT will reduce the system dynamic range.
5-18
Summary of Contents for 8712C
Page 1: ...I I User s Guide HP 8712C and HP 8714C RF Network Analyzers I ...
Page 17: ...I 1 Installing the Analyzer ...
Page 35: ...I 2 Getting Started ...
Page 54: ...I 3 Making Measurements ...
Page 81: ......
Page 119: ...4 Using Instrument Functions ...
Page 182: ...Using Instrument Functions Customizing the Display Figure 4 24 Expanded Display 4 64 ...
Page 223: ...5 Optimizing Measurements ...
Page 244: ...6 Calibrating for Increased Measurement Accuracy ...
Page 280: ...7 Automating Measurements ...
Page 298: ......
Page 362: ...8 Front Rear Panel ...
Page 373: ......
Page 381: ......
Page 386: ... 9 w I Suftkey Reference ...
Page 477: ...I 10 Specifications and Characteristics ...
Page 501: ...11 Safety and Regulatory Information ...
Page 508: ...I 12 preset State and Memory Allocation ...
Page 527: ...Index ...
Page 559: ...Y X 9 91 YYW m m IiH rn 9 91 Z zeroing detectors 6 15 Index 33 ...