8 Troubleshooting – Possible faults
151
FA070
Dosing contai-
ner overfilling
•
The overfilling cover was
opened
•
Faulty limit switch
•
Connection cable faulty
•
Material blockage
•
Close overfilling cover
•
Check limit switch
•
Check the electrical connec-
tion
•
Remedy material blockage
•
Press the
Acknowledge fault
key
FA071
Foreign bodies
in rotary feeder
•
Foreign bodies in feed sys-
tem or stoker auger
•
Transformer in control cabi-
net faulty
•
Motor is faulty
•
Check for foreign bodies
•
Moving forwards and back-
wards in the manual menu
•
Check transformer in control
cabinet
•
Check the motor
•
Press the
Acknowledge fault
key
FA073
Fuel bunker door
end switch
•
Fuel bunker door was ope-
ned
•
Faulty limit switch
•
Connection cable faulty
•
Close the door
•
Check limit switch
•
Check the cable
•
Check the electrical connec-
tion
•
Press the
Acknowledge fault
key
FA074
Check material
stop limit
switch
•
Limit switch triggered 1 fil-
ling at start
•
Check the fill level indicator
•
Press the
Acknowledge fault
key
FA077
Overfilling of
pellet auger
•
The overfilling cover was
opened
•
Faulty limit switch
•
Connection cable faulty
•
Material blockage
•
Close overfilling cover
•
Check limit switch
•
Check the electrical connec-
tion
•
Remedy material blockage
•
Press the
Acknowledge fault
key
FA078
Overfilling of
pellet auger at
hose junction
position 1
•
The overfilling cover was
opened
•
Faulty limit switch
•
Connection cable faulty
•
Material blockage
•
Close overfilling cover
•
Check limit switch
•
Check the electrical connec-
tion
•
Remedy material blockage
•
Press the
Acknowledge fault
key
No.
Fault
Cause
Remedy
Table 8/1 - Faults (continuation)