HDG Bavaria GmbH 07/2008
HDG Compact 99 - 200 - Version 1 - en
7 Cleaning and servicing the heating system – Procedure
135
✎
See chapter “6 Using the heating system”, section “6.9 MANUAL
menu”, paragraph “Ash removal, main cleaning, dust removal and
cleaning system”.
✓
The cleaning shaft and the turbulators are cleaned.
HDG C
OMPACT
150 - 200
1.
Set the engage switch to “0”.
✎
See the chapter entitled “6 Using the heating system”, section “6.3
Switching off the heating system”.
2.
Allow the fire in the heating system to burn out and cool down.
3.
Loosen both M8 screws (3) with an SW13 spanner and remove the
cover (1) of the cleaning system motor.
4.
Pull out both the other cover sections (2) towards the front or
back.
5.
Move the cleaning system downward in manual operation.
6.
Hold the
F4
key under the
On
command down longer than three
seconds.
✓
The cleaning system moves downward.
Warning!
Danger of injury
The elements of the cleaning shaft lid are heavy.
When dismantling or assembling the three elements of the
cleaning shaft lid, make sure hands and arms are not crushed.
Figure 7/14 - Removing the cover
3
2
1
✎
See chapter “6 Using the heating system”, section “6.9 MANUAL
menu”, paragraph “Ash removal, main cleaning, dust removal
and cleaning system”.