6 Using the heating system – TIME menu
100
HDG Compact 99 - 200 - Version 1 - en
©
HDG Bavaria GmbH 07/2008
C
ENTRAL
ASH
REMOVAL
SYSTEM
-
SETTING
LAG
TIME
This submenu is used to set the lag time for the central ash removal
system.
✎
See “Procedure” in this section.
S
ERVICE
MESSAGES
-
SETTING
REMINDER
TIME
This submenu can be used to set various times at which service mes-
sages should appear.
•
WA Empty ash box
– When the set runtime of the ash removal auger is exceeded,
the warning "Please empty ash box" appears. The heating
system does not shut off at the appearance of this warning. The
"0" setting deactivates this function.
•
ST Empty ash box
– When the set runtime of the ash removal auger is exceeded,
the fault message "Ash box full" appears. The heating system
shuts off at this fault. The "0" setting deactivates this function.
•
WA Lubricate screw stoker
– When the set runtime of the screw stoker is exceeded, the war-
ning "Please lubricate screw stoker" appears. The heating
system does not shut off at the appearance of this warning. The
"0" setting deactivates this function.
•
WA Lubricate cleaning system
– When the set runtime of the cleaning system is exceeded, the
warning "Please lubricate cleaning system" appears. The hea-
ting system does not shut off at the appearance of this war-
ning. The "0" setting deactivates this function.
✎
See “Procedure” in this section.
This is an optional submenu and only available with central ash re-
moval systems.
Time
3-13
Ash conveyor lag time
:
120 /
0 s
END