6 Using the heating system – Performing the chimney sweep test
121
✓
The display changes to the
Service 5-01
submenu.
2.
Press the
F4
key under the “
Chimney sweep test
” symbol.
✓
You are now in the
Chimney sweep mode 5-02
submenu.
3.
Press the
F3
key under the
30%
command to start the chimney
sweep test.
4.
Press the
F34
key under the
100%
command to start the chimney
sweep test in nominal load operation.
✓
The
Heating
message appears in the display.
✓
Once the specified temperatures have been reached, the display
shows the
Measurement enabled
message.
✓
The measurement is carried out.
Service
5-01
Digital inputs 0-15
00000000 00000000
Digital outputs 0-15
00000001 00000000
END
Chimney sweep test
5-02
Heating OFF
Enabling boiler temperature :
60°C
Enabling comb. chamber temp.:
325°C
Measurement time
:
75 / 0 m
30%
100%
END
When operating the heating system without an accumulator, the
chimney sweep test can also be carried out in partial load mode
with 30% of the nominal thermal power.
Press the
F6
key under the
End
command to cancel the chimney
sweep test.
The chimney sweep test is also cancelled if the specified time for the
measurement is exceeded.