HDG Bavaria GmbH 07/2008
HDG Compact 99 - 200 - Version 1 - en
6 Using the heating system – SERVICE menu
109
S
ETTING
REVERSE
FEEDING
AND
IGNITION
TEMPERATURE
•
Delay reverse movement
– This submenu is used to change the delay in the reversal of the
feed system. The feed system reverses for overcurrent if the ro-
tary feeder becomes blocked. The change of rotational direc-
tion is then delayed by this amount of time.
•
Reverse moving runtime
– The running time of the reversal in which the feed system runs
backwards can also be corrected. This value is limited to a ma-
ximum of three seconds.
•
Reverse moving attempts
– The maximum number of possible reverse attempts can be set.
•
Ignition temperature
– If the temperature in the hot combustion chamber exceeds
this value, the HDG Control does not switch on the ignition fan
for starting the heating system.
✎
See “Procedure” in this section.
Service
5-05
Delay reverse movement
:
00.7 s
Reverse moving runtime
:
01.0 s
Reverse attempts
:
3 x
Ignition temperature
:
150 °C
END