8 Troubleshooting – Possible faults
150
HDG Compact 99 - 200 - Version 1 - en
©
HDG Bavaria GmbH 07/2008
FA057
Exhaust tempe-
rature too high
•
Exhaust temperature above
set maximum value
•
Press the
Acknowledge fault
key
FA058
Ash box full
•
Set monitoring time for ash
removal augers exceeded
•
Empty ash box
•
Reset time in the parameter
3-14
with
RESET
•
Press the
Acknowledge fault
key
FA065
Feed system
overfilling
•
The overfilling cover was
opened
•
Faulty limit switch
•
Connection cable faulty
•
Material blockage
•
Close overfilling cover
•
Check limit switch
•
Check the electrical connec-
tion
•
Remedy material blockage
•
Press the
Acknowledge fault
key
FA066
Overfilling
dosage
•
The overfilling cover was
opened
•
Faulty limit switch
•
Connection cable faulty
•
Material blockage
•
Close overfilling cover
•
Check limit switch
•
Check the electrical connec-
tion
•
Remedy material blockage
•
Press the
Acknowledge fault
key
FA067
Overfilling
Delivery system
•
The overfilling cover was
opened
•
Faulty limit switch
•
Connection cable faulty
•
Material blockage
•
Close overfilling cover
•
Check limit switch
•
Check the electrical connec-
tion
•
Remedy material blockage
•
Press the
Acknowledge fault
key
FA068
Overfilling
Trough auger 2
•
The overfilling cover was
opened
•
Faulty limit switch
•
Connection cable faulty
•
Material blockage
•
Close overfilling cover
•
Check limit switch
•
Check the electrical connec-
tion
•
Remedy material blockage
•
Press the
Acknowledge fault
key
FA069
Lateral auger
overfilling
•
The overfilling cover was
opened
•
Faulty limit switch
•
Connection cable faulty
•
Material blockage
•
Close overfilling cover
•
Check limit switch
•
Check the electrical connec-
tion
•
Remedy material blockage
•
Press the
Acknowledge fault
key
No.
Fault
Cause
Remedy
Table 8/1 - Faults (continuation)