6 Using the heating system – SERVICE menu
111
✎
See “Procedure” in this section.
I
GNITION
FAN
You can set the phase and form in which the ignition fan is patched
in to aid the start-up procedure. Three settings are available in each
phase:
– Off: The ignition fan is not yet activated in this phase.
– Fan: Only the fan of the ignition fan is activated.
– Fan + heating: The ignition fan switches on completely (fan +
heating).
✎
See “Procedure” in this section.
F
UEL
QUANTITY
1
ST
M
ODIFYING
FILLING
AND
AIR
START
SETTING
•
Fuel quantity 1st filling
– Change the fuel quantity of the first filling in heating up mode.
•
Air start setting
– These parameters determine the air quantity of the primary air
and secondary air for heating up mode.
✎
See “Procedure” in this section.
Service
5-07
Dosage pause_min.
: 5.0 /
-1.5 s
Dosage impulse_min.
: 5.0 / 5.0 s
Feed system lag time
: 60.0 /
.0 s
Feed system lead time
:
0.0 s
END
Ignition fan
5-08
with 1st filling
:
Off
with pre-ventilation
:
Off
with heating up
:
Off
END
Service 5-09
Fuel quantity 1st filling
:
25.0 %
Primary air
start
25 %
Secondary air start
:
80 %
END