Built-in capacitor of actuator
Data retention time
Data retention
time
Approx. 30 min. after the
power is cut off
Conditions
After 3 h of charging, ambient
temperature 25
℃
, axis
stopped
How to replace the backup battery
If [UA 91: Low battery power] displays, replace the battery by following the procedure below:
1
Open the operation panel cover.
2
Remove the battery.
3
Set the new battery by placing it in the battery holder with the positive side facing down.
4
Push the battery all the way in and close the panel cover.
With a 13-bit absolute encoder or a 17-bit absolute encoder (SHA20 and FHA-Cmini
series)*, UA91 will be automatically reset after the battery is replaced.
With a 17-bit absolute encoder (SHA series (excluding SHA20)), UA91 will be reset by
resetting the alarm and reconnecting the power after the battery is replaced.
* In Version 2.x and earlier, after the battery is replaced, turning the power back ON releases
UA91.
Exercise caution to prevent the battery cable from getting caught when closing
the panel cover.
Panel cover
Battery holder
Summary of Contents for H A - 800A
Page 60: ...2 6 Wiring the host device 2 21 4 2 2 1 9 8 7 6 9 8 Installation wiring...
Page 86: ...3 6 Normal operation 3 25 4 3 3 1 9 8 7 6 9 8 Startup...
Page 152: ...5 8 Connection example in control mode 5 35 1 2 3 4 5 6 7 8 9 10 11 Appe I O signals...
Page 166: ...6 1 Operating display panel 6 13 11 10 9 4 7 6 5 4 3 2 1 Panel display and operation...
Page 206: ...8 2 Function extension parameter 8 17 1 2 3 4 5 6 7 8 9 10 11 Appe System parameter mode...
Page 222: ...9 2 Details of test mode 9 15 1 2 3 4 5 6 7 8 9 Test mode...
Page 270: ...11 2 Warnings and remedial actions 11 17 1 2 3 4 5 6 7 8 9 10 11 Appe Troubleshooting...
Page 271: ...1 16 Chapter 12 Option Options you can purchase as necessary are explained 12 1 Option 12 1...
Page 276: ...12 1 Option 12 5 1 2 3 4 5 6 7 8 12 Option...