UA91
Battery
voltage low
The backup
battery voltage
has dropped to
DC2.8V or
below.
(1) Voltage drop due to consumption
of backup battery
(2) Short-circuit the encoder battery
wire
(3) HA-800A driver control circuit
error
(4) Encoder failure
(1) Replace with a new battery.
(2) Repair the wire.
(3) Replace the HA-800A driver.
(4) Replace the actuator.