8-2 Function extension parameter
8-3
1
2
3
4
5
6
7
8
9
10
11
Appe
Syst
em
p
aram
et
er
m
ode
8-2
Function extension parameter
The function extension parameters SP40 onward are explained below. For details on other system parameters,
refer to [Chapter 5 I/O signals].
Parameters
No
Name
Default
SP40
CP9-CP3 output signal setting
00
SP41
Control mode switching setting
0
SP42
Command pulse input pattern setting
0
SP43
Multiplication of 2-phase input
1
SP44
Electronic gear 1 numerator
1
SP45
Electronic gear 1 denominator
1
SP46
Electronic gear 2 numerator
1
SP47
Electronic gear 2 denominator
1
SP48
Deviation clear upon servo-ON
1
SP49
Allowable position deviation
*1
SP50
Command polarity
0
SP51
Speed input factor
*1
SP52
Zero clamp
0
SP53
Torque input factor
100
SP54
Status display setting
d00
SP55
DB enable/disable setting
1
SP56
External speed limit enable/disable
0
SP57
External torque limit enable/disable
0
SP58
System reservation *3
-
SP59
Angle compensation enable/disable setting
0
SP60
Automatic positioning gain setting
enable/disable setting
*1
SP61
Encoder monitor output pulses
*1
SP62
SP63
System reservation *3
-
SP64
Regenerative resistor selection (HA-800-24
only)
0
SP65
FWD/REV inhibit operation
0
SP66
Absolute encoder function setting
*4
SP67
Output shaft divide function setting
0
SP68
System reservation *3
-
SP69
Feed-forward control function setting
*1
SP70
to
SP79
System reservation *3
-
*1: It varies depending on the applicable actuator. Refer to the values of applicable actuator that
are the targets of Appendix 1 [Default settings].
*2: The system parameters (SP00 to 79) are enabled by reconnecting the control power supply
after changing the setting.
*3: Do not change the parameters that are in the system reserved areas. The default setting of the
system reservation may vary depending on the model/version. If the set values change when
the parameters are transferred between different models, it does not affect the product functions.
To perform the data comparison with the backed up parameter files or writing the backed up
parameter files to the driver using PSF-800 communication software, refer to [10-5. Saving and
reading set values].
*4: HA-800A-*D: SP66=0, HA-800A-*E: SP66=1
Summary of Contents for H A - 800A
Page 60: ...2 6 Wiring the host device 2 21 4 2 2 1 9 8 7 6 9 8 Installation wiring...
Page 86: ...3 6 Normal operation 3 25 4 3 3 1 9 8 7 6 9 8 Startup...
Page 152: ...5 8 Connection example in control mode 5 35 1 2 3 4 5 6 7 8 9 10 11 Appe I O signals...
Page 166: ...6 1 Operating display panel 6 13 11 10 9 4 7 6 5 4 3 2 1 Panel display and operation...
Page 206: ...8 2 Function extension parameter 8 17 1 2 3 4 5 6 7 8 9 10 11 Appe System parameter mode...
Page 222: ...9 2 Details of test mode 9 15 1 2 3 4 5 6 7 8 9 Test mode...
Page 270: ...11 2 Warnings and remedial actions 11 17 1 2 3 4 5 6 7 8 9 10 11 Appe Troubleshooting...
Page 271: ...1 16 Chapter 12 Option Options you can purchase as necessary are explained 12 1 Option 12 1...
Page 276: ...12 1 Option 12 5 1 2 3 4 5 6 7 8 12 Option...