A-2 Regenerative resistor
A-16
A
ppendi
x
Apx
Actuator model No.
SHA58A-SG
SHA65A-SG
Actuator reduction ratio
81
101
121
161
81
101
121
161
Combined driver
HA-800A-24D/E-200
HA-800A-24D/E-200
Max. rotational
speed
r/min
37.0
29.7
24.8
18.6
34.6
27.7
23.1
17.4
Actuator inertia
moment
(no brake)
kg
・
m
2
96
149
214
379
110
171
245
433
kgf
・
cm
・
s
2
980
1520 2180 3870
1120 1740 2500 4420
Actuator inertia
moment
(with brake)
kg
・
m
2
106
165
237
420
120
187
268
475
kgf
・
cm
・
s
2
1090 1690 2420 4290
1230 1910 2740 4850
Allowable load
inertia moment
when a built-in
regenerative
resistor is used
(repeat cycle)
kg
・
m
2
111
173
249
441
128
200
288
508
kgf
・
cm
・
s
2
1133 1765 2541 4500
1306 2041 2939 5184
Allowable load
inertia moment
when a built-in
regenerative
resistor is used
(non-repeat cycle)
kg
・
m
2
212
330
474
840
240
374
536
950
kgf
・
cm
・
s
2
2160 3360 4830 8570
2440 3810 5460 9690
Allowable load
inertia moment
when an external
regenerative
resistor is used
kg
・
m
2
290
450
640
1140
360
560
810
1420
kgf
・
cm
・
s
2
2900 4600 6500 11600
3700 5700 8200 14500
External
regenerative
resistor
Connect two RH500_20ΩJ in parallel, or
connect four RH500_10ΩJ in series and
parallel.
Connect two RH500_20ΩJ in parallel, or
connect four RH500_10ΩJ in series and
parallel.
Actuator model No.
SHA20A-CG
SHA25A-CG(-S)
Actuator reduction ratio
50
80
100
120
160
50
80
100
120
160
Combined driver
HA-800A-3D/E-200
HA-800A-3D/E-200
Max. rotational
speed
r/min
120
75
60
50
37.5
112
70
56
46.7
35
Actuator inertia
moment
(no brake)
kg
・
m
2
0.21
0.53
0.82
1.2
2.1
0.50
1.3
2.0
2.9
5.1
kgf
・
cm
・
s
2
2.1
5.4
8.0
12
22
5.1
13.0
20
29
52
Actuator inertia
moment
(with brake)
kg
・
m
2
0.23
0.60
0.94
1.3
2.4
0.60
1.5
2.4
3.4
6.1
kgf
・
cm
・
s
2
2.4
6.1
9.6
14
24
6.1
16
24
35
62
Allowable load
inertia moment
when a built-in
regenerative
resistor is used
(repeat cycle)
kg
・
m
2
0.93
2.3
3.6
5.1
7.7
0.72
1.8
2.9
4.1
7.3
kgf
・
cm
・
s
2
9.5
23
37
52
78
7.3
18
30
42
74
Allowable load
inertia moment
when a built-in
regenerative
resistor is used
(non-repeat cycle)
kg
・
m
2
1.6
3.8
4.8
5.8
7.7
1.6
3.9
6.2
8.8
16
kgf
・
cm
・
s
2
16.3
39
49
59
78
16.3
40
63
90
163
Allowable load
inertia moment
when an external
regenerative
resistor is used
kg
・
m
2
2.4
(3.8) (4.8) (5.8) (7.7)
5.6
8.8
11
14
20
kgf
・
cm
・
s
2
25
(39)
(49)
(59)
(78)
57
90
112
144
201
External
regenerative
resistor
RH220B33ΩJ
RH220B33ΩJ
Summary of Contents for H A - 800A
Page 60: ...2 6 Wiring the host device 2 21 4 2 2 1 9 8 7 6 9 8 Installation wiring...
Page 86: ...3 6 Normal operation 3 25 4 3 3 1 9 8 7 6 9 8 Startup...
Page 152: ...5 8 Connection example in control mode 5 35 1 2 3 4 5 6 7 8 9 10 11 Appe I O signals...
Page 166: ...6 1 Operating display panel 6 13 11 10 9 4 7 6 5 4 3 2 1 Panel display and operation...
Page 206: ...8 2 Function extension parameter 8 17 1 2 3 4 5 6 7 8 9 10 11 Appe System parameter mode...
Page 222: ...9 2 Details of test mode 9 15 1 2 3 4 5 6 7 8 9 Test mode...
Page 270: ...11 2 Warnings and remedial actions 11 17 1 2 3 4 5 6 7 8 9 10 11 Appe Troubleshooting...
Page 271: ...1 16 Chapter 12 Option Options you can purchase as necessary are explained 12 1 Option 12 1...