E2 Adjustable Speed Driver 

Microprocessor Controlled 
IGBT Drive 
Inverter Motor Speed Regulator
Operating Manual
 

 

High Performance Adjustable Speed Micro Drives 

 

E2 Series 
 

      110V 

        0.2~0.75KW 
      ( 0.53~1.6KVA )

 

 

      220V  

        0.2~2.2KW 
      ( 0.53~4.0KVA )

 

 

      440V 

        0.75~2.2KW 
       ( 1.7~4.0KVA )

 

 
 

Содержание T-Verter E2 Series

Страница 1: ...er Microprocessor Controlled IGBT Drive Inverter Motor Speed Regulator Operating Manual High Performance Adjustable Speed Micro Drives E2 Series 110V 0 2 0 75KW 0 53 1 6KVA 220V 0 2 2 2KW 0 53 4 0KVA 440V 0 75 2 2KW 1 7 4 0KVA ...

Страница 2: ...ent 7 2 Sample Model No Identification 8 3 Specifications 9 4 Wiring 15 5 Dimensions Location of terminal block 18 Chapter 3 Software Index 1 Keypad Operating Instructions 30 2 Parameters List 31 3 Parameter Function Description 32 4 Malfunction Indication and Countermeasure 44 5 General Malfunction Examination Method 47 Chapter 4 Trouble Shooting Procedure 1 Flow Chart 48 2 Maintenance Examinatio...

Страница 3: ...verter or the mechanical system might be damaged if misused Danger z Risk of electric shock The DC link capacitors remain charged for five minutes after power has been removed It is not permissible to open the equipment until 5 minutes after the power has been removed z Do not connect any wires when the inverter is powered Do not check parts and signals on circuit boards when the inverter is in op...

Страница 4: ...check the following when you receive and unpack the inverter z The model and capacity of the inverter is the same as those specified on your order z Is there any damage caused by transportation If so do not apply the power Contact TECO s sales representatives if any of the above problems happened ...

Страница 5: ...ammable object Intall on nonflammable objects such as metal z If several inverters are placed in the same control panel provide heat removal means to maintain the temperature below 50 degree C to avoid overheat or fire Warning This product complies with IEC 61800 3 with built in Filter in an unrestricted distribution and with use of external filter in restricted distribution Under some environment...

Страница 6: ...switch FWD REV button Attention the restart operation is irrelevant with F_23 F_24 1 When F_10 0 the inverter will not start after restart 2 When F_10 1 and the external switch FWD REV button is OFF the inverter will not start after restart When F_10 1 and the external switch FWD REV button is ON the inverter will start automatically after restart Attention Base on safety reason please turn off th...

Страница 7: ...ffective Caution z Do not touch heat generating components such as heat sinks and brake resistors z The inverter can drive the motor from low speed to high speed Verify the allowable speed ranges of the motor and the associated machinery z Note the settings related to the braking unit z Do not check signals on circuit PCB while the inverter is running Caution Risk of electric shock The DC link cap...

Страница 8: ...nvironments Keep away from rain or where dripping water may get into the inverter Avoid metal dust and dusty environments Avoid massive vibration Avoid excessive direct heat Avoid where environmental temperatures are too high Keep away from high electrical magnetic waves or ultra high waves Keep away from radioactive matter Keep away from flammable material oil ...

Страница 9: ... foreign dusts flocks or metal scraps from entering interior z Avoid electric magnetic interference soldering or power machinery z Avoid vibration if vibration cannot be avoided an anti rattle mounting device should be installed to reduce vibration z If the inverter is installed in an enclosed control panel please remove the shield sticker located at the top of the inverter This will allow additio...

Страница 10: ...eries Power Voltage Horse Power Rated Model Type Power Supply Filter Option Enclosure Type Ventilation Installation Direction Front View 1 110V 2 220V 4 440V P2 0 25 Hp P5 0 5 Hp 01 1 Hp 02 2 Hp 03 3 Hp M CPU Version V1 6 H CPU Version V1 9 or above 1 Single Phase 3 Three Phase Blank Single or Three Phase F with filter Blank without filter N4S meet IP65 NEMA4 Standard with Switch N4 meet IP65 NEMA...

Страница 11: ... 4 2 3 4 2 7 5 10 5 Capacity KVA 0 53 0 88 1 6 2 9 4 0 Rated Weight Kg 0 76 0 77 0 8 1 66 1 76 Input Voltage Max Single phase 200 240V 10 15 50 60Hz 5 Single Three phases 200 240V 10 15 50 60Hz 5 Output Voltage Max Three phases 200 240V Proportional to input voltage Dimension W H D mm 72 132 118 118 143 172 EMC Specification Class A Single Phase Filter built in Model E2 401 H3xx 402 H3xx 403 H3xx ...

Страница 12: ...rol Other function Decelerate or free run stop Auto reset DC braking frequency Voltage Time can be setup by constants Display Three digital LED display frequency inverter parameter fault record program version Operating temperature 10 40O C without shield sticker 10O C 50O C Humidity 0 95 RH non condensing Vibration Under 1 G 9 8 m s2 EMC specification EN61800 3 A11 EN50178 UL UL508C Overload prot...

Страница 13: ...0mm2 Terminal screw M3 Wire dimension 14AWG 2 0m m2 Terminal screw M3 M4 Wire dimension 3 5mm2 Terminal screw M4 Wire dimension 3 5mm2 Terminal screw M4 Signal Terminal TM2 1 11 Wire dimension 0 75mm2 18 AWG Terminal screw M3 Use copper conductors only size field wiring based on 80 degrees C wire only z Please utilize three phase squirrel cage induction motor with appropriate capacity z If the inv...

Страница 14: ... need a magnetic contactor When performing functions such as external control and auto restart after power failure or when using a brake controller install a magnetic contactor z Do not use the magnetic contactor as the run stop switch for the inverter AC Line Reactor for power quality z When inverters are supplied with high capacity above 600KVA power source a AC reactor can be connected to impro...

Страница 15: ...uctor to the shielding z Use a metal clamp to connect the shielding from the motor cable with the metal grounding plate Now there is a perfect high frequency earth connection between frequency inverter grounding plate and EMI filter z Keep the distance between the frequency inverter and EMI filter as short as possible 30cm if longer use a shielded cable with a metal coupling nut and a metal clamp ...

Страница 16: ...tance must be under 50m C The grounding terminal of the inverter must be correctly grounded in compliance with 200V class type three grounding z Grounding wire should be wired in accordance to electrical equipment AWG with the length of the grounding wire as short as possible z The grounding wire of the inverter must not be grounded together with other large current loads such as soldering machine...

Страница 17: ...ire Terminations to the Inverter must be made with either UL listed field wiring lugs or UL listed crimp type ring terminals Note Only for 202 203 401 402 403 P R L1 L L2 L3 N FWD REV SP1 RST 12V 10V MVI 0 10V 0 20 4 20mA 0V FM FM note Braking Resister Option SW1 1 2 3 U T1 V T2 W T3 1 2 CON2 AC Input IM Trip Relay Test Points Grounding 3 4 6 7 5 Multi Function Inputs 8 9 10 11 FM Speed Pot 10kΩ 0...

Страница 18: ...16 z External 24V supply TM2 FWD REV SP1 RST 0V 3 4 6 7 10 24V ...

Страница 19: ...erminal refer to F_21 Connection point rated capacity 250VAC 1A 30VDC 1A 3 FWD FW 4 REV RE Operation control terminals refer to F_03 5 12V 12 Common point of terminal 3 4 6 7 6 SP1 SP 7 RESET RS Multifunction input terminals refer to F_19 8 10V Power terminal for potentiometer Pin 3 9 Analog input wire Wiper Analog frequency signal input terminal Pin 2 of potentiometer or positive terminal of 0 10...

Страница 20: ...to 1 Dimensions Location of terminal block E2 1P2 1P5 101 2P2 2P5 201 Unit mm DEMESIONS MODEL A B C D E F G E2 1P2 1P5 101 2P2 2P5 201 132 116 130 8 2 118 61 72 NOTE For safety reason we strongly recommend users to remove the M4 grounding screw then screw the enclosed metal frame grounding terminal on the same location to make a grounding bar to ensure good earth protection See NOTE ...

Страница 21: ... Installation of class B Filter M 4 x 1 4L Φ 4 5 T Y P 2 5 0 6 0 0 7 6 0 156 0 145 0 134 0 See NOTE of Page 18 Unit mm LENGTH MODEL A B C D E2 202 203 401 402 403 143 1 127 5 140 8 0 LENGTH MODEL E F G E2 202 203 401 402 403 171 7 108 118 ...

Страница 22: ...20 Mounting Instructions Inverter with class B filter mounted Inverter with class B filter Din rail mounted kit ...

Страница 23: ...f inverter Step2 Push the DIN Rail forward until the middle rib grips firmly with back panel Step1 Use a small screwdriver inserting it into the middle rib of DIN Rail and press the screwdriver in order to remove the DIN Rail from inverter Install Drive Dismounting Drive 1 Pull the mounting plate downward 2 Rotate the inverter module to dismount it First place the groove on the back of module on t...

Страница 24: ...22 E2 1P2 1P5 101 2P2 2P5 201 N4X IP65 TYPE STOP 0 1 R RUN ENT DATA FUN DSP RESET F 0 140 6 5 54 140 6 5 54 123 4 4 86 UNIT mm inch ...

Страница 25: ...23 E2 202 203 401 402 403 N4X IP65 TYPE UNIT mm inch 180 7 09 211 5 8 33 ...

Страница 26: ...ning signal before power on again after power supply interrupted Otherwise injury may result FOR E2 1P2 201 N4S TYPE Please always remain RE or FW switch at OFF position In order to keep inverter has no running signal before power on again after power supply interrupted Otherwise injury may result 3 PHASE IM 10V VI 0V FW RE 12V L1 L2 T1 T2 T3 POWER SWITCH REV 0 FWD SWITCH Potentiometer AC 100 120 ...

Страница 27: ...NS EMC MOUNTING T1 L2 L1 T2 T3 Motor cable T1 T2 T3 L1 L2 Power supply cable 200mm Cutting Length of cable shield Cable shielding connected to ground clamp EMC MOUNTIING Length Max 2M Note TM2 Remote control cable should be connect to ground screw ...

Страница 28: ... terminals Power supply cable Motor cable EMCMOUNTIING Power supply cable L1 L2 Cutting Length of cable shield 200mm Cable shielding connected to ground clamp Note TM2 Remote control cable should be connect to ground screw Length Max 2M T1 T2 T3 Motor cable T1 T2 T3 Motor cable Power supply cable L1 L2 ...

Страница 29: ...are only for E2 202 403 N4S TYPE CIRCUIT DIAGRAM NOTE 1 Input source single phase L1 L L2 N ensuring that it is connected to a 200 240 supply or three plase L1 L L2 N L3 ensuring that it is connected to a 200 240 380 480V supply 2 Output Motor three phase T1 T2 T3 Caution Do not start or stop the inverter using the main circuit power FOR E2 202 403 N4S TYPE Please always remain REV 0 FWD switch at...

Страница 30: ...f EMC conformed waterproof IP65 ferrite core 1 pc of metal fastener 1 pc of MF Zin 5 C screw CAUTION if application use require to meet EMC regulation you MUST first constrain the motor cables close the ferrite core onto the motor cable outside the plastic enclosure as stated in the above diagram Please also note the length of the Motor cable CANNOT exceed 5M under EMC regulation ...

Страница 31: ...f EMC conformed waterproof IP65 ferrite core 1 pcs of metal fastener 1 pcs of MF Zin 5 C screw CAUTION if application use requires meeting EMC regulation you MUST first constrain the motor cables close the ferrite core onto the motor cable outside the plastic enclosure as stated in the above diagram Please also note the length of the Motor cable CANNOT exceed 5M under EMC regulation ...

Страница 32: ...void damaging keypad Brief keypad operation flowchart Note 1 Displayed setting of frequency when stopped Display output frequency when running Note 2 The setting of the frequency can be modified either when stopped or when running FREQ 1 FREQ RESET DATA ENT RUN STOP DSP FUN POWER LED F DSP FUN DSP FUN F DATA ENT READ END DATA ENT WRITE AFTER 0 5 SEC 2 ...

Страница 33: ... 0 Keypad 1 Terminal TM2 1 0 1 0 35 Frequency Control 11 0 Keypad 1 Terminal 0 10v 0 20mA 2 Terminal 4 20mA 1 0 2 0 36 Carrier frequency control 12 Carrier Frequency Setting 1 1 5 1 10 4 5 36 Torque compensation 13 Torque compensation gain 0 1 0 0 10 0 0 0 36 1 Stop method 14 0 controlled deceleration stop 1 free run to stop 1 0 1 0 37 15 DC braking time 0 1S 0 0 25 5S 0 5S 37 16 DC braking inject...

Страница 34: ...t 28 0 enable 1 disable 1 0 1 1 42 5 Software version 29 CPU program version 43 Fault Log 30 Fault log for three faults 43 NOTE 1 Indicate this parameter can be adjusted during running mode 2 Please refer to F_25 3 If the setting range is above 100 the setting unit becomes 1 4 New function for CPU version V1 9 and above 5 New function for CPU version V2 1 and above Parameter function description F...

Страница 35: ...tting 0 Forward 1 Reverse Although there is no Forward Reverse push button on the digital control panel it is possible to adjust forward reverse function by changing the F_04 setting NOTE When F_22 1 Reverse is disabled the F_04 cannot be set to 1 The keypad indication would display LOC F_03 0 control method F_03 1 control method 3 FWD Stop 4 REV Stop 3 Run Stop 4 FWD REV 5 COM 5 COM Forward F_03 ...

Страница 36: ...cation High starting torque Decreasing torque F_5 1 2 3 V F pattern Specification 60Hz System Application General Application High starting torque Decreasing torque F_5 4 5 6 V F pattern F_5 B C 1 4 10 8 2 5 15 10 5 3 6 25 7 7 V V V V V V 100 B C 100 B C 100 B C 100 B C 100 B C 100 B C 1 2 5 50 120 1 25 50 120 1 2 5 50 120 1 3 0 60 120 1 3 0 60 120 1 30 60 120 Hz Hz Hz Hz Hz Hz ...

Страница 37: ... and the multifunction input terminal is ON the inverter operates at sp1 frequency F_08 2 When F_19 or F_20 1 and the multifunction input terminal is ON the inverter operate at jog frequency F_09 3 The priority of reading frequency setting is Jog Sp1 Keypad setting or external frequency signal using a speed pot F_10 Start Stop Control 0 Keypad 1 Terminal TM2 NOTE When F_10 1 Terminal Control emerg...

Страница 38: ...1 4 kHz 5 8 kHz 9 15 kHz 1 2 5 kHz 6 10 kHz 1 10 16 kHz 1 3 6 kHz 7 12 kHz 1 4 7 2 kHz 8 14 4 kHz 1 NOTE 1 Available for CPU version V1 9 and above 2 If F_12 7 10 the inverter must operator with low load Although an IGBT TYPE inverter can provide a low audible noise level during its operation it is possible that the switching of the high carrier frequency may interfere with external electronic com...

Страница 39: ...set frequency setup by F_16 after this the output voltage level that is set in the F_17 will determine the amount of DC voltage that s injected into the motor The time duration to perform this stopping function is setup in F_15 If F_14 1 The inverter stops output immediately after receiving the stop command The motor will enter into a free running state until it comes to a complete stop 1 2 5 3 0 ...

Страница 40: ...peeds the heat dissipation efficiency is lower The electronic thermal activation level is also reduced to change from curve 1 to curve 2 in Figure 3 Choose the appropriate F_05 setting according to the applied motor to reach the desired performance 2 The electronic thermal protecting for inverter 1 When the load is within 103 of the inverters rated current the operation continues When the load rea...

Страница 41: ...eds to decelerate and stop ignoring the setting of F_14 The inverters E S light will flash after stopping After the emergency stop signal is deactivated turn the RUN switch OFF and then ON again to cycle it F_10 1 Or push the RUN key F_10 0 The inverter will then resume operation and restart If the emergency stop signal is removed before the inverter stops the inverter will still execute the emerg...

Страница 42: ... Speed Signal 3 F_21 3 Fault signal Terminal1 and2 of TM2 are activated at CPF OL1 OL2 OCS OCA OCC Ocd Ocb OVC LVC OHC Hz Time F_21 1 Terminal 1 2 on F_21 2 Terminal 1 2 on F_22 Reverse Lock Out 0 REV command 1 REV command Lock out NOTE When F_04 is set to 1 reverse F_22 cannot be set to 1 in order to properly lockout a motors direction F_04 must be set at 0 before setting F_22 to 1 ...

Страница 43: ...entary power loss is long the inverter must be restart manually The operation of the inverter is based on the setup of F_10 and the condition of external switch 4 When restart the inverter the operation of the inverter is based on the setup of F_10 and the condition of external switches FWD REV button 1 When F_10 0 the inverter will not start after restart 2 When F_10 1 and the external switch FWD...

Страница 44: ...ocess is complete 50Hz operation 2 When F_25 is set to 020 all parameters are restored to factory settings The settings of F_05 4 and F_06 60 F_25 is restored back to 000 after the reset process is complete 60Hz operation F_26 SP2 1 200Hz Multi speed2 Reference to F_19 F_20 F_27 SP3 1 200Hz Multi speed3 Reference to F_19 F_20 F_28 Direct start 0 Direct start enable when remote Run command on 1 Dir...

Страница 45: ... xxx Indicates the earliest malfunction in the record 2 After entering the F_30 function the x xx trip record will be displayed first After that press button and you can read activity in a chronological order xx x Æ xxx Æ x xx Æ consecutively 3 After entering F_30 function if the RESET button is pressed the trip record will be cleared Indication display and 4 When the content of trip indicates O C...

Страница 46: ...er supply 2 Return the inverter for repair Inverter over heat while not operating 1 Detection circuit defective 2 Environment over heat or poor ventilation 1 Return the inverter for repair 2 Improve ventilation 2 Manual reset operative malfunctions Auto Reset inoperative INDICATION CONTENT POSSIBLE CAUSE COUNTERMEASURE Over current at stop condition Detection circuit malfunction Return the inverte...

Страница 47: ...ut side Over current at deceleration Deceleration setting too short Adjust to use a longer acceleration time Over current at breaking DC Breaking frequency breaking voltage or breaking time setting too long Adjust to reduce settings of F_15 F_16 or F_17 Over voltage at operation deceler ation 1 Deceleration time setting too short or inertial loading too large 2 Power supply voltage variation too l...

Страница 48: ...stop signal is activated through the multi function input terminal the inverter decelerates and stops Inverter flashes E S after stops Refer to instruction for F_19 for detail External BASE BLOCK When the external BASE BLOCK signal is activated through the multifunction terminal the inverter stop output immediately and flash b b for indication Refer to instruction for F_19 for detail Keypad Operat...

Страница 49: ...n the output terminals T1 T2 and T3 correct z Operate by digital Motor operate in opposite direction Is the wiring for the forward and reverse signals correct z Wiring should be in accordance with the U V W terminals of motor Is the wiring for analog frequency input correct z Examining the wiring and correct it Is the operation mode setting correct z Examining the wiring and correct it Motor opera...

Страница 50: ...tion indication is Any sign of burnt of breakage Is the primary circuitry DM normal Is the primary circuitry I G B T normal Replace defective board Is LED2 illuminate Is the DC input voltage of control power supply normal Is the control power source 5V normal Replace control board digital controller Is replacing control board solve the problem Examining component with sign of burnt or breakage Rep...

Страница 51: ...r is out of order YES Carry out parameter initialization Designate operation control method Frequency instruction setting Does the controller displays frequency setting Is there voltage output on UVW terminals The inverter is normal now Replace control board Replace control board Is replacing control board correct the problem Yes the problem has been corrected No The problem is not corrected YES N...

Страница 52: ... B T Is the current detector normal NO YES NO ABNORMAL Is there any malfunction indication Input frequency setting Is there output voltage on UVW terminals Connect motor and proceed with operation Is there any malfunction indication Is output current of all phases in balance condition The inverter is normal now Replace defective PCB Replace control board Replace detector Replace control board Repl...

Страница 53: ...ion instruction Replace defective board NO NO Is there any malfunction indication Input frequency instruction Is there output voltage on T1 T2 and T3 terminals Connect motor Is the motor operating Is there any malfunction indication Is output current of all phases in balance condition The inverter is normal now Replace control board Replace control board Replace control board Is the problem correc...

Страница 54: ...MCCB Power source abnormality Poor wiring Place the operation switch to RUN position Is the T1 T2 T2 T3 T3 T1 output voltage in balance condition ABNORMAL NO YES YES When the motor is not connected and the voltoge differences between wires are within 3 can be treated as in balance condition Normal within 10 of nominal value NO NO Is the voltage between L1 L2 power input terminals normal NO Is ther...

Страница 55: ...ltage level between T1 T2 T2 T3 and T3 T1 normal YES Operate at low speed for a long time Select another motor Remove obstacle affecting motor cooling Correct the connection NO YES YES E2 malfunction Poor connection between E2 and motor Is there over loading condition or the load current exceeds rated current NO YES YES NO NO ...

Страница 56: ...ce load Increase E2 and motor capacity Reduce loading variation or install fly wheel Improve mechanical system NO YES YES E2 malfunction During acceleration or deceleration NO Is the voltage level between T1 T2 T2 T3 and T3 T1 normal Is the acceleration deceleration time setting appropriate E2 malfunction NO NO Not appropriate Appropriate YES The differences between different wires are within 3 ...

Страница 57: ...circuitry normal Measure voltage by multi meter Voltage level conforming specification Improve input power source Is the tighten parts secured Is there any sign of breakage on the terminal panel Inverter external terminal mounting screw Is there any obvious rusty condition Visual inspection Use screwdriver to verify screw tightness No abnormality Tighten loose screw or return for repair Is it defo...

Страница 58: ...heck out mounting screws on every terminal and parts Tighten loose screws 3 Dielectric strength test a Remove all conducting wires between Drive and outside world Power must be turned OFF b The dielectric strength test inside Drive should be carried out only for T VERTER major circuitry Use DC 500V high resistance meter Measured resistance should be higher than 100M ohm CAUTION Do not perform diel...

Страница 59: ... Ii Moving iron Input power Pi Power meter P W1 Input power factor PFi Calculate power factor by the input voltage input current and input power Output voltage Vo Rectifier Moving iron not allowed Maximum voltage difference between wires under 3 Output Current Io Moving iron Under the inverter rated current Output power Po Power meter Po W3 W4 Output power factor A1 V1 W1 A4 A5 A6 V4 V5 V6 W3 W4 L...

Страница 60: ...P5 101 2P2 2P5 201 E2 202 203 401 402 403 Specification of Braking Resister and Input Reactor Input AC Reactor MODEL Braking transistor build in Braking resister build in Torque of braking Model of braking resister Current A Inductance mH E2 2P2 x1xx X X 20 Note 1 3 7 0 E2 2P5 x1xx X X 20 Note 1 5 2 4 2 E2 201 x1xx X X 20 Note 1 9 4 2 1 E2 202 Hxx X 20 BRN2 202 19 1 1 E2 203 Hxx X 20 BRN2 203 25 0...

Страница 61: ...2 Hxxx BRN2 202 1 5 150 100 10 119 215 40 20 325 225 70 5 2 1 E2 203 Hxxx BRN2 203 2 2 200 70 9 116 165 60 30 200 195 80 3 2 E2 401 H3xx BRN2 401 0 75 60 750 8 125 115 40 20 200 195 80 1 1 E2 402 H3xx BRN2 401 1 5 150 400 10 119 215 40 20 325 225 70 5 2 1 E2 403 H3xx BRN2 403 2 2 200 250 8 128 165 60 30 200 195 80 3 2 Note 1 Braking level 385 770Vdc for E2 200 400 series 2 Braking resister mountin...

Страница 62: ... APPLICATION TELEPHONE ADDRESS F_ Value Setting F_ Value Setting F_ Value Setting F_00 F_11 F_22 F_01 F_12 F_23 F_02 F_13 F_24 F_03 F_14 F_25 F_04 F_15 F_26 F_05 F_16 F_27 F_06 F_17 F_28 F_07 F_18 F_29 F_08 F_19 F_30 F_09 F_20 F_10 F_21 ...

Страница 63: ... 0 22 1 to 26 0 TIC 3 5 5 5 NH 82 3 5 5 5 12 10 M8 R5 5 8 61 2 to 66 0 53 0 to 57 2 TIC 3 5 5 5 NH 82 M4 R8 4 12 2 to 14 10 4 to 12 1 TIC 8 NOP 60 M5 R8 5 20 4 to 24 17 7 to 20 8 TIC 8 NOP 60 M6 R8 6 25 5 to 30 0 22 1 to 26 0 TIC 8 NOP 60 8 8 M8 R8 8 61 2 to 66 0 53 0 to 57 2 TIC 8 NOP 60 M4 R14 4 12 2 to 14 10 4 to 12 1 TIC 14 NOP 60 150 M5 R14 5 20 4 to 24 17 7 to 20 8 TIC 14 NOP 60 150 M6 R14 6...

Страница 64: ...his manual may be modified when necessary because of improvement of the product modification or changes in specifications this manual is subject to change without notice Distributor 10F No 3 1 Yuancyu St Nangang District Taipei City 115 Taiwan Tel 886 2 6615 9111 Fax 886 2 6615 0933 ...