Gree GMV6 HR DC Inverter VRF Units Service Manual
11
Model
-
GMV-VQ2295WM/C-
X
GMV-VQ2349WM/C-
X
GMV-VQ2405WM/C-
X
GMV-VQ2460WM/C-
X
Packing
dimensions
(W × D × H)
mm
1400×830×1855+
1400×830×1855+
1400×830×1855+
1400×830×1855
1400×830×1855+
1400×830×1855+
1400×830×1855+
1400×830×1855
1400×830×1855+
1400×830×1855+
1400×830×1855+
1400×830×1855
1400×830×1855+
1400×830×1855+
1400×830×1855+
1400×830×1855
Net weight
kg
325+385+385+385
385+385+385+385
385+385+385+385
385+385+385+385
Gross weight
kg
340+400+400+400
400+400+400+400
400+400+400+400
400+400+400+400
Note:
①
Rated cooling capacity test conditions: indoor 27
℃
DB/19
℃
WB, outdoor 35
℃
DB; without
height drop between units.
②
Rated heating capacity test conditions(Tdesingnh): indoor 20
℃
DB, outdoor -10
℃
DB/-11
℃
WB; without height drop between units. Max heating capacity test conditions: indoor 20
℃
DB,
outdoor 7
℃
DB/6
℃
WB; without height drop between units.
③
The total capacity of connected indoor units must be in the range of 50%~135% of the outdoor
unit capacity. The relevant parameters can be corrected by referring to the unit capacity
correction table.
④
The above parameters are tested based on the standard connection pipe length. In the actual
project, the parameters should be corrected referring to the capacity correction for the long
connection pipe of units.
⑤
Specifications may be changed due to product improvement. Please refer to nameplates of the
units.
2.2 Parameters of Mode Exchange Box
Model
NCHS1D
NCHS2D
NCHS4D
NCHS8D
Numbers of branches
unit
1
2
4
8
Maximum numbers of
connectable IDUs
Per branch
unit
8
8
8
8
Total
unit
8
16
32
64
Maximum capacity of
connectable IDUs
Per branch
kW
16
16
16
16
Total
kW
16
28
45
85
Power supply
220-240V ~ 50/60Hz
Piping connections
ODU
Liquid
mm
Φ9.52
Φ9.52
Φ12.7
Φ15.9
High
pressure gas
mm
Φ19.05
Φ19.05
Φ22.2
Φ22.2
Low
pressure gas
mm
Φ22.2
Φ22.2
Φ28.6
Φ28.6
IDU
Liquid
mm
Φ6.35/9.52
Φ6.35/9.52
Φ6.35/9.52
Φ6.35/9.52
Gas
mm
Φ12.7/15.9
Φ12.7/15.9
Φ12.7/15.9
Φ12.7/15.9
Outline dimension(W×D×H)
mm
340×388×250 340×388×250
460×388×250 784×388×250
Summary of Contents for GMVVQ1015WM/C-X
Page 418: ...Gree GMV6 HR DC Inverter VRF Units Service Manual 416 GMV VQ400WM C X GMV VQ450WM C X...
Page 420: ...Gree GMV6 HR DC Inverter VRF Units Service Manual 418 NCHS1D...
Page 421: ...Gree GMV6 HR DC Inverter VRF Units Service Manual 419 NCHS2D...
Page 422: ...Gree GMV6 HR DC Inverter VRF Units Service Manual 420 NCHS4D...
Page 423: ...Gree GMV6 HR DC Inverter VRF Units Service Manual 421 NCHS8D...
Page 426: ...Gree GMV6 HR DC Inverter VRF Units Service Manual 424 6 1 2 Heating Operation...
Page 427: ...Gree GMV6 HR DC Inverter VRF Units Service Manual 425 6 1 3 Main body Cooling...
Page 428: ...Gree GMV6 HR DC Inverter VRF Units Service Manual 426 6 1 4 Main body Heating...
Page 430: ...Gree GMV6 HR DC Inverter VRF Units Service Manual 428 6 2 2 Heating Operation...
Page 431: ...Gree GMV6 HR DC Inverter VRF Units Service Manual 429 6 2 3 Main body Cooling...
Page 432: ...Gree GMV6 HR DC Inverter VRF Units Service Manual 430 6 2 4 Main body Heating...
Page 433: ...JF00304244...