Triggering
Trigger hold off
Disable channel trigger for 1 to 65 535 samples after trigger detected
Maximum hold off time depends on sample rate
Interval timer
Modes
Less than, trigger when rate is too low
More than, trigger when rate is too high
Between, trigger when rate between lower and upper limit
Not between, trigger when rate is not between lower and upper limit
Interval timers
Start timer and width Timer
Timer value
1 to 65 535 samples
Event counter
Counts channel trigger events before card trigger is activated
1 to 256 trigger events
Alarm Output
Selection per card
User selectable On/Off
Alarm modes
Basic or Dual
Basic
Above or below level check
Dual (level)
Outside or within bounds check
Alarm levels
Levels
Maximum 2 level detectors
Resolution
16 bit (0.0015%) for each level
Alarm output
Active during valid alarm condition, output supported through mainframe
Alarm output delay
515 µs
±
1 µs + maximum 1 sample period using decimal time base
503 µs
±
1 µs + maximum 1 sample period using binary time base
Real
-
Time Analysis
StatStream
®
Patent Number : 7,868,886
Each channel includes real
-
time extraction of Maximum, Minimum, Mean, Peak
-
to
-
Peak,
Standard Deviation and RMS values
Supports the real
-
time live scrolling and scoping of waveform displays and the real
-
time
meters while recording
Supports fast displaying and zooming within extremely large recordings
Supports fast calculations of statistical channel information
Acquisition Modes
Single sweep
Triggered acquisition to on
-
board memory without sample rate limitations; for single
transients or intermittent phenomena. No aggregate sample rate limitations.
Multiple sweeps
Triggered acquisition to on
-
board memory without sample rate limitations; for repetitive
transients or intermittent phenomena. No aggregate sample rate limitations.
Slow
-
Fast Sweep
Identical to single sweep acquisition with additional support for fast sample rate switches
during the post
-
trigger segment of the slow rate single sweep settings. No aggregate sample
rate limitations. Slow
-
Fast Sweep is not supported by the RT
-
FDB calculators.
Continuous
Direct storage to PC or mainframe controlled hard disk without file size limitations; triggered
or un
-
triggered; for long duration recorder type applications. Aggregate sample rate
limitations depend on Ethernet speed, PC used and data storage media used.
Dual
Combination of Multiple sweeps and Continuous; recorder type streaming to hard disk with
simultaneously triggered sweeps in on
-
board memory. Aggregate sample rate limitations
depend on Ethernet speed, PC used and data storage media used.
In Dual mode the RT
-
FDB calculators sample based results are only calculated for the
sweep sections of the recorded data. Due to the asynchronous nature of cycle based results,
all cycle based results are continuously stored and used in both the sweep as well as the
continuous sections of the recording.
GEN3t
I3995-3.1 en HBM: public
531