10.3.4
Dual
-
window trigger mode
The dual
-
window trigger mode is a more sophisticated version of the window
trigger mode. Now both levels are used as an arm/trigger/disarm level. This
allows the trigger detector to react to a dip in both directions.
A
A
A/T/D
2
1
A/T/D
A/T/D
A/T/D
Figure 10.7:
Dual
-
window trigger mode
A
Trigger
Diagram
1
shows one situation, whereas Diagram
2
shows the other situation
with the same settings. In this mode, the following conditions determine the
trigger result:
l
Level crossing in opposite set direction = arm level
l
Level crossing in set direction = disarm when other level is armed
l
Level crossing in set direction = trigger when level is armed
Since this is true for both levels, a “dip” in both directions is detected, as shown
in Diagrams
1
and
2
Relevant settings for this mode:
l
Mode: dual
-
window
l
Primary level: any value within the input range
l
Secondary level: any value within the input range
l
Direction: positive or negative for primary level; secondary level is
automatically set to the opposite direction
l
Hysteresis: any relevant value is used for both levels.