218
Upgrade and Maintenance Manual
TX1330
M1
Processors
11.1
Basic information
Supported processors
The system board is equipped with one LGA 1150 socket for dual and quad
Core Intel Xeon E3-1200v3 processor series CPUs.
11.2
Upgrading or replacing the processor
V
CAUTION!
Processors are extremely sensitive to electrostatic discharge and must
be handled with care. After a processor has been removed from its
protective sleeve or from its socket, place it upside down on a
nonconducting, antistatic surface. Never push a processor over a
surface.
11.2.1 Preliminary steps
Ê
"Disabling BitLocker functionality" on page 69
Ê
"Disabling SVOM boot watchdog functionality" on page 70
Ê
If applicable,
"Locating the defective server" on page 43
Ê
"Shutting down the server" on page 46
Ê
"Disconnecting the server from the mains" on page 46
Ê
"Getting access to the component" on page 47
Ê
"Removing the fan module" on page 151
Field Replaceable Unit
(FRU)
Hardware: 15 minutes
Software: 5 minutes
Tools:
Phillips PH2 / (+) No. 2 screw driver
Summary of Contents for Server PRIMERGY TX1330 M1
Page 18: ...Upgrade and Maintenance Manual TX1330 M1 Content ...
Page 30: ...30 Upgrade and Maintenance Manual TX1330 M1 Before you start ...
Page 98: ...98 Upgrade and Maintenance Manual TX1330 M1 Basic software procedures ...
Page 120: ...120 Upgrade and Maintenance Manual TX1330 M1 Power supply ...
Page 158: ...158 Upgrade and Maintenance Manual TX1330 M1 System fan and air duct ...
Page 216: ...216 Upgrade and Maintenance Manual TX1330 M1 Main memory ...
Page 336: ...336 Upgrade and Maintenance Manual TX1330 M1 Appendix ...