Power supply
6.3.2
Removing a hot-plug power supply unit
I
Note for servers using CMA (Cable Management Arm)
Regarding of removing power supply units, additional tasks are needed,
due to an interference between CMA stopper and the power supply units.
Ê
Unlock the CMA stopper.
Ê
Remove the CMA stopper with the mounted crossbar.
Ê
Support the CMA stopper, the crossbar and the CMA including cables
with your right hand.
Ê
Remove the power supply unit and install a dummy cover into the
empty bay.
Ê
Remount the complete assembly (CMA stopper, crossbar and CMA)
into the rail.
6.3.2.1
Preliminary steps
Ê
Disconnect the power cord from the hot-plug power supply unit (see
"Disconnecting the server from the mains" on page 46
).
Customer Replaceable Unit
(CRU)
Hardware: 5 minutes
Tools:
tool-less