112
Upgrade and Maintenance Manual
TX1330
M1
Power supply
I
Note for servers using CMA (Cable Management Arm)
Regarding of replacing power supply units, additional tasks are needed,
due to an interference between CMA stopper and the power supply units.
Ê
Unlock the CMA stopper.
Ê
Remove the CMA stopper with the mounted crossbar.
Ê
Support the CMA stopper, the crossbar and the CMA including cables
with your right hand.
Ê
Remove the power supply unit and install the new power supply unit
carefully.
Ê
Remount the complete assembly (CMA stopper, crossbar and CMA)
into the rail.
6.3.3.1
Preliminary steps
Ê
"Locating the defective server" on page 43
Ê
Only when replacing a power supply unit in a non-redundant configuration:
"Shutting down the server" on page 46
Ê
Only when replacing a power supply unit in a non-redundant configuration:
"Disconnecting the server from the mains" on page 46
6.3.3.2
Removing the defective hot-plug power supply unit
Ê
Identify the defective power supply unit using the server management
software.
Ê
Remove the power supply unit as described in
"Removing a hot-plug power
supply unit" on page 110
.
6.3.3.3
Installing the new hot-plug power supply unit
Ê
Install the power supply unit as described in section
"Installing a hot-plug
power supply unit" on page 108
.
Summary of Contents for Server PRIMERGY TX1330 M1
Page 18: ...Upgrade and Maintenance Manual TX1330 M1 Content ...
Page 30: ...30 Upgrade and Maintenance Manual TX1330 M1 Before you start ...
Page 98: ...98 Upgrade and Maintenance Manual TX1330 M1 Basic software procedures ...
Page 120: ...120 Upgrade and Maintenance Manual TX1330 M1 Power supply ...
Page 158: ...158 Upgrade and Maintenance Manual TX1330 M1 System fan and air duct ...
Page 216: ...216 Upgrade and Maintenance Manual TX1330 M1 Main memory ...
Page 336: ...336 Upgrade and Maintenance Manual TX1330 M1 Appendix ...