TX1330 M1
Upgrade and Maintenance Manual
325
Appendix
Indicator Status
Description
A
GEL
(Global Error
LED)
off
no critical event (non CSS component)
orange on prefailure detected (non CSS component)
orange
flashing
non CSS component failure
Possible reasons:
– sensors report overheating
– sensor is defective
– CPU error
– software reports an error
B
CSS
(Customer
Self Service)
off
no critical event (CSS component)
yellow on
prefailure detected (CSS component)
yellow
flashing
CSS component failure
C
Identification
blue on
Localizes the server
blue
flashing
Local monitor off
D
Memory
off
memory module operational
orange on memory module failure
E
System fans
off
fan running
orange on fan failure
F
PCI card
off
PCI card operational
orange on PCI card failure
G
AUX power
yellow on
AUX voltages are within range
H
iRMC
green
flashing
iRMC S4 management controller is
operational