TX1330 M1
Upgrade and Maintenance Manual
209
10
Main memory
Safety notes
V
CAUTION!
●
Do not install unsupported third party memory modules. For further
information on supported memory modules, refer to section
"Basic
information" on page 209
.
●
Memory modules remain hot after shutdown. Wait for components to
cool down before installing or removing memory modules to prevent
burns.
●
Do not insert and remove memory modules repeatedly. Doing so may
cause failures.
●
Pressing out the securing clips on the memory module connector will
eject the installed memory module. To prevent damage and injuries
eject memory modules carefully without applying excessive force.
●
For further information, please refer to chapter
"Important
information" on page 31
.
10.1 Basic information
– The system board is equipped with four memory slots.
– The system has to be equipped with at least one memory module.
– Supported memory modules:
DDR3L 1333 or 1600 unbuffered single rank (SR) or dual rank (DR)
UDIMMs with ECC
– Supported capacities: 2 GB, 4 GB or 8 GB.
– Maximum amount of RAM: 32 GB
Summary of Contents for Server PRIMERGY TX1330 M1
Page 18: ...Upgrade and Maintenance Manual TX1330 M1 Content ...
Page 30: ...30 Upgrade and Maintenance Manual TX1330 M1 Before you start ...
Page 98: ...98 Upgrade and Maintenance Manual TX1330 M1 Basic software procedures ...
Page 120: ...120 Upgrade and Maintenance Manual TX1330 M1 Power supply ...
Page 158: ...158 Upgrade and Maintenance Manual TX1330 M1 System fan and air duct ...
Page 216: ...216 Upgrade and Maintenance Manual TX1330 M1 Main memory ...
Page 336: ...336 Upgrade and Maintenance Manual TX1330 M1 Appendix ...