System board and components
14.5.1 Preliminary steps
Ê
"Disabling BitLocker functionality" on page 69
Ê
"Disabling SVOM boot watchdog functionality" on page 70
Ê
"Locating the defective server" on page 43
Ê
"Shutting down the server" on page 46
Ê
"Disconnecting the server from the mains" on page 46
Ê
Disconnect all external cables.
Ê
"Getting access to the component" on page 47
Ê
"Removing the fan module" on page 151
14.5.2 Removing the defective system board
Ê
Remove all cables from the system board.
Ê
Remove the following components from the system board:
– Heat sink: see
section "Removing the processor heat sink" on page 219
I
Leave the processor on the defective board for now.
– Memory modules: refer to section
"Removing memory modules" on
page 211
I
Ensure to take note of the memory modules’ mounting positions
for reassembly.
– Expansion cards: refer to the section
"Removing expansion cards" on
page 179
I
Ensure to take note of the controllers’ mounting positions and
cable connections for reassembly.
– UFM: refer to section
"Removing the UFM" on page 259
I
Remove the UFM spacer from the defective system board and
fasten it to the UFM with the UFM screw.
Summary of Contents for Server PRIMERGY TX1330 M1
Page 18: ...Upgrade and Maintenance Manual TX1330 M1 Content ...
Page 30: ...30 Upgrade and Maintenance Manual TX1330 M1 Before you start ...
Page 98: ...98 Upgrade and Maintenance Manual TX1330 M1 Basic software procedures ...
Page 120: ...120 Upgrade and Maintenance Manual TX1330 M1 Power supply ...
Page 158: ...158 Upgrade and Maintenance Manual TX1330 M1 System fan and air duct ...
Page 216: ...216 Upgrade and Maintenance Manual TX1330 M1 Main memory ...
Page 336: ...336 Upgrade and Maintenance Manual TX1330 M1 Appendix ...