138
Upgrade and Maintenance Manual
TX1330
M1
Hard disk drives / solid state drives
For further information, please refer to the "ServerView Suite RAID
Management" user guide.
Ê
If applicable,
"Removing the HDD bay cover" on page 55
7.3.4.2
Removing a 3.5-inch HDD module
Figure 56: Removing a 3.5-inch HDD module
Ê
While pressing down on the locking button (1) fold up the lever (2).
I
Thereby, the HDD module is pushed out of its drive bay by about 1 cm
and disconnected from the SAS / SATA backplane.
Ê
Wait about 30 seconds to allow the hard disk drive to spin down.
Ê
Pull the HDD module completely out of its bay.