Chapter 4 Function/System Settings and Display
4.3 Network Management > show event-notification
ETERNUS CLI User’s Guide
Copyright 2015 FUJITSU LIMITED
P2X0-1030-09ENZ0
523
■
Example(s)
The following example displays the parameters that have been set for event notification:
CLI> show event-notification
[Severity: Error Level] E-mail SNMP Host REMCS Syslog AIS Connect
Parts Error Notify Notify Notify(OPMSG) - Do not notify Notify
Disk Error Notify Notify Notify - Do not notify Notify
Temperature Error Notify Notify Notify(OPMSG) - Do not notify Notify
End of battery life Notify Notify Notify(OPMSG) - Do not notify Notify
Rebuild/Copyback w/ redundant - - Notify(OPMSG) - - -
Rebuild/Copyback w/o redundant - - Notify(OPMSG) - - -
Redundant Copy End Notify Notify Notify(OPMSG) Notify Do not notify Notify
Complete rebuild Notify Notify Notify(OPMSG) - Do not notify Notify
Bad data Notify Notify Notify(OPMSG) - Do not notify Notify
Pinned data Notify Notify Notify(OPMSG) - Do not notify Notify
Not ready Notify Notify Notify(OPMSG) - Do not notify Notify
Remote Path Error Notify Notify Notify(OPMSG) Notify Do not notify Notify
REC Buffer Halt (Path Error) Notify Notify - Notify Do not notify Notify
REC Buffer Halt (Overload) Notify Notify - Notify Do not notify Notify
REC Buffer Halt (Other Error) Notify Notify - Notify Do not notify Notify
Thin Provisioning Pool Rate Notify Notify - - Do not notify Do not notify
Redundant Copy Start Finish Notify Notify Notify(OPMSG) Notify Do not notify Notify
Copy Session Error Notify Notify - Notify Do not notify Notify
SED Network Error Notify Notify - Do not notify Do not notify Notify
[Severity: Warning Level] E-mail SNMP Host REMCS Syslog
Parts Warning Notify Notify Notify - Do not notify Notify
Disk Warning Notify Notify Notify - Do not notify Notify
Temperature Warning Notify Notify Notify - Do not notify Notify
Battery life Warning Notify Notify Notify - Do not notify Notify
[Severity: Information Level] E-mail SNMP Host REMCS Syslog
Recovery module Do not notify Do not notify - - Do not notify Do not notify
Temperature restoration Do not notify Do not notify - - Do not notify Do not notify
User login/logout Do not notify Do not notify - - Do not notify Do not notify
Operated RAID Group Do not notify Do not notify - - Do not notify Do not notify
Added/Released Hot Spare Do not notify Do not notify - - Do not notify Do not notify
Operated Volume Do not notify Do not notify - - Do not notify Do not notify
Power off/on Apply Firmware Do not notify Do not notify - - Do not notify Do not notify
SDP Usage Rate Over Lv1 Do not notify Do not notify - - Do not notify Do not notify
SDP Usage Rate Over Lv2 Do not notify Do not notify - - Do not notify Do not notify
SDP Usage Rate Over Lv3 Do not notify Do not notify - - Do not notify Do not notify
Copy Table Size Usage Rate Over Do not notify Do not notify - - Do not notify Do not notify
Trial copy license expired Notify Notify - - Do not notify Do not notify
No Free Space on ODX Volume Do not notify Do not notify - - Do not notify Do not notify
SED Network Error Recovered Notify Notify - - Do not notify Notify
FC CA Port Link Status Changed Do not notify Do not notify - - Do not notify Notify
Host Login Over Do not notify Do not notify - - Do not notify Notify