Chapter 3 Configuration Settings and Display
3.3 RAID Group Management > set eco-schedule
ETERNUS CLI User’s Guide
Copyright 2015 FUJITSU LIMITED
P2X0-1030-09ENZ0
136
■
Example(s)
-event-to
Optional. This parameter specifies that the ECO schedule will end at a specific time. The format
is "hhmm". "hh" is the ending hour (00 – 23) and "mm" is the ending minute (00 or 30). If
omitted, the existing setting is not changed.
The following example adds ECO schedule event #2 in the ECO schedule named "SC001":
CLI> set eco-schedule -schedule-name SC001 -event-number 2 -event-type every-day -event-from 0600 -event-to
1800
The following example changes the ECO schedule name. The new ECO schedule name is "SC002_NEW":
CLI> set eco-schedule -schedule-name SC001 -name SC002_NEW