![Fluke OC3port Plus User Manual Download Page 75](http://html.mh-extra.com/html/fluke/oc3port-plus/oc3port-plus_user-manual_2309945075.webp)
OC3port Plus
Users Manual
3-28
4. Set the baud rate on the OC3port Plus:
a.
Press the
OPTIONS
key. The
OPTION SELECTIONS
menu is displayed.
b.
Press the
Down Arrow
key until the
RS-232 Speed
option is on the selection
line. For example:
OPTION SELECTIONS
Parameter Set 1
RS-232 Speed 96
Scroll Method WIN
za036f.eps
c.
Press the
Right
or
Left Arrow
key to select the interface speed (
96
= 9600
baud,
24
= 2400 baud,
12
= 1200 baud) you want.
Note
For the best results, select the baud rate that matches the fastest rate
on your printer or PC. The change takes effect immediately. The
OC3port Plus is configured with the baud rate you selected.
5. Configure your printer or PC as follows:
•
Baud rate
Match OC3port Plus
•
Data bits
8
•
Stop bits
1
•
Parity
None
•
Flow control
Xon/Xoff or CTS/RTS
•
Local echo (terminals)
On
•
Line feed (terminals)
Carriage return = line feed
(inbound /outbound).
To test the connection, press the
ESC
key. The OC3port Plus resets and returns
you to the introductory display. The printer or PC running the terminal emulation
program prints or displays OC3port Plus.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com