Testing ATM Networks
Quality of Service Tests
6
6-49
8.
Make sure that the
Cell Loss
option is on the selection line. Then, press
ENTER
. The
Cell Loss
submenu is displayed:
CELL LOSS:
- - - - - - - - - - - - - - - - - - - - - - - -
Start Cell Loss STD
Setup Cell Loss
za135f.eps
9.
Press the
Down Arrow
key to move the
Setup Cell Loss
option to the selection
line. Then, press
ENTER
. The
CELL LOSS PARAMETERS
menu is displayed:
CELL LOSS PARAMETERS
- - - - - - - - - - - - - - - - - - - - - - - -
Duration: 005.0
RT Delay: 0.05
za136f.eps
10. Make sure that the
Duration
parameter
is on the selection line. This parameter
determines the amount of time for each burst of cell loss transmission. The
values of this parameter range from
0.1
to
300
seconds. The default value is
5.0
seconds.
11. Press the
EDIT
key to enter Edit mode and supply the desired value for the
Duration
parameter. Press
ENTER
when you are done to save the change.
12. Press the
Down Arrow
key to move the
RT Delay
option to the selection line.
This parameter sets the maximum amount of time that the OC3port Plus
should wait for the return of transmitted cells. The value of
RT Delay
ranges
from .
01
seconds to
9.99
seconds. The default value is
.05
seconds.
13. Press the
EDIT
key to enter Edit mode and supply the desired value for
the RT
Delay
parameter. Press
ENTER
when you are done to save the change.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com