OC3port Plus
User Manual
6-68
8
Press
ENTER
. You see this display:
STS-3c SETUP:
- - - - - - - - - - - - - - - - - - - - - - -
Path Auto YEL OFF
Line Auto FERF OFF
za015f.eps
Note
The default form for expressing the
PCR
value is in megabits per
second (
MBS
). You can change this form to a percent
(%BW
) or cells
per second (
CPS
). For information on how to do this, see "Changing
the Format for the PCR and SCR" in Chapter 5.
9. You are in Edit mode as indicated by the flashing number in the first position
of the
PCR
field. Press the arrow keys to supply the desired
PCR
value. When
you finish, press
ENTER
to save the change.
You have completed the setup for a 1-point CDV test.
Running a 1-point CDV Test
To run a 1-point CDV test:
1.
Press the
ATM
key. The
ATM SELECTIONS
menu is displayed.
2.
Make sure that the
Quality of Service
option is on the selection line. Then,
press
ENTER
. The
QUALITY OF SERVICE
submenu is displayed.
3.
Press the
Down Arrow
key to move the
1PT Cel Dly Var
option to the selection
line, as in the following:
QUALITY OF SERVICE
Cell Loss
1Pt Cel Dly Var 1
2Pt Cel Dly Var 1
za151f.eps
The
1Pt Cel Dly Var
option has four settings (1-4), which respectively
correspond to the four receive filters.