Scanning Circuits for ATM Activity
The OC3port Plus can automatically scan an ATM network and record the virtual
paths and channels on which ATM activity is found. This type of scan is best
suited for testing networks when you know little about the virtual circuit
configurations.
During the test, the OC3port Plus systematically scans the input signal, changing
its receive filters and "don’t care" conditions until all areas of cell activity have
been isolated and identified. The scan takes place in two phases. In the first phase,
each VPI is checked for cell activity and a list of active VPIs is constructed. In the
second phase, each active path in the VPI list is scanned for circuit cell activity.
This section first shows you how to set up an ATM activity scan. Then, it shows
you how to run the test and describes the types of results generated by the OC3port
Plus. Finally, it shows you how to print an activity scan report.
Setting Up an ATM Activity Scan
Note
The information in this section shows you how to configure the
OC3port Plus so that it performs more efficient and quicker scanning
of ATM circuits. If you prefer, you can skip this setup information
and go directly to "Running an ATM Activity Scan", which follows
this section.
This three-part setup procedure shows you how to do the following:
1.
Configure the VPI and VCI address ranges.
If you know the range of virtual path and virtual channel addresses, it is
advisable to use these to set the upper and lower search boundaries, thereby
limiting the address space over which the OC3port Plus searches. By doing
this, you can increase the efficiency of the scan and effectively reduce the
duration of the scan.
2.
Determine the duration of the scan.
You can select a scan rate that determines the amount of time spent searching
for individual addresses.
3.
Turn on the activity detection alarm.
You can configure the unit to issue an audible alarm (a "beep") whenever
activity is found within the search boundaries you establish.