![Fluke OC3port Plus User Manual Download Page 117](http://html.mh-extra.com/html/fluke/oc3port-plus/oc3port-plus_user-manual_2309945117.webp)
OC3port Plus
Users Manual
5-12
You can configure the OC3port Plus to fill the payloads of cells on any of the
eight transmission streams with fixed bit patterns (
FIXED
), with OAM cells
(
OAM
), or, when doing BERT testing, with pseudo-random or user-defined
patterns (
BERT
). You can also program the tester to mix OAM cells with other
traffic.
5. Press the
Left
or
Right Arrow
key to select the desired setting:
Note
To generate BERT cells, the
PAYLOAD
parameter must be set to
BERT
.
The setting you selected is now the current value for the
PAYLOAD
parameter.
You have completed configuration of the transmission stream’s payload.
Step 3: Set the transmission source, transmission rate, and traffic shape
parameters
1.
On the setup menu for
TRANSMIT STREAM 1,
press the
Up Arrow
key to move
the
SOURCE
parameter to the selection line, as in:
TRANSMIT STREAM: 1
NAME:XMITHDR_1
SOURCE CBR
VPI:0000
za068f.eps
The OC3port Plus supports four different transmission sources. These
configure the traffic pattern to be:
•
'&6'SRWXERX&MX6EXI
•
:&64SMWWSR:EVMEFPI&MX6EXI4SMWWSR
•
4(94VSXSGSP(EXE9RMXWMQYPEXIWRIX[SVOJMPIXVEJJMG
•
:&6&9678:EVMEFPI&MX6EXI&YVWX
•
OFF
Note
The transmission source you choose determines which traffic
parameters (that is,
PCR, SCR, MBS
, and
CDV LIM
) you can use. See
Table 5.3 for a list of traffic parameters that are permitted for each
source.
For detailed explanations and illustrations of the use of these
parameters, see Appendix B.