![Fluke OC3port Plus User Manual Download Page 147](http://html.mh-extra.com/html/fluke/oc3port-plus/oc3port-plus_user-manual_2309945147.webp)
OC3port Plus
User Manual
6-16
4. Press the
Down Arrow
key to locate these options:
•
Set A to Filter
•
Set B to Filter
For example:
CELL CAPTURE
Review Cell Capture
Set A to Filter 1
Set B to Filter 1
za094f.eps
The OC3port Plus has two cell capture filters, A and B, which are used to
control the capturing of cells. You can set each capture filter to match any one
of the four receive filters, or you can set both capture filters to match the same
receive filter. By default, both capture filters are set to Receive Filter 1.
5. With the
Set A to Filter
option on the selection line, press the
Left
or
Right
Arrow
key to set it to the desired receive filter.
6. Press the
Down Arrow
key to move the
Set B to Filter
option to the selection
line. Then, press the
Left
or
Right Arrow
key to set it to the desired receive
filter.
7. Press the
Down Arrow
key to locate the following options, which represent the
trigger conditions (the criteria for storing cells):
•
Trigger On Cnd1
•
Or Cnd2
These two options are used together. They set up an either/or condition for
determining the criteria for storing cells.
Trigger On Cnd1
has these four settings:
•
ANY
Begins storing cells when any ATM cell is received.
•
A
Begins storing cells when a cell matching the receive filter set for
capture filter A is received.
•
!A
Begins storing cells when a cell matching any receive filter
except the one set for capture filter A is received.
•
OFF
Tells the OC3port Plus not to evaluate this condition.