OC3port Plus
User Manual
6-10
3. Make sure that the
Monitor ATM
option is on the selection line. Then, press
ENTER
. You see the result display for the receive filter. For example:
Note
If you press the
CLEAR
key while viewing a result display, all
counters are set to zero.
R1: CIRCUIT A
125 0016 PT0 CP1 G0
1.76E+09 C 353207CPS
146.76MBPS 100.00%BW
za082f.eps
This display contains the following information:
•
Line 1
Identifies the receive filter (R1) by name (in this case, "Circuit
A").
•
Line 2
Provides the header information (values of the VPI, VCI, PT,
CLP, and GFC settings).
•
Line 3
Provides both the total count of ATM cells received that match
the receive filter and a count of matching cells received during
the previous second.
•
Line 4
Indicates the cell reception rate in megabits per second and the
percent bandwidth.
4.
Press the
Right Arrow
key. You see additional information on Line 4 for the
receive filter:
R1: CIRCUIT A
125 0016 PT0 CP1 G0
1.76E+09 C 353207CPS
AVER CPS 353166.70
za083f.eps