Section 7: Model 9100: Specifications
7-13
Final Width = 215mm
7.6.9
Waveshape Harmonic Analysis
(Peak values as a percentage of the Fundamental's Peak Value)
Harmonic
Square
Impulse
Triangular
Trapezoidal
1
100.00
100.00
100.00
100.00
3
-33.32
60.71
11.11
-22.22
5
19.98
14.93
4.000
4.000
7
-14.25
-7.616
2.041
2.041
9
11.07
-6.746
1.235
-2.469
11
-9.040
-0.826
0.826
0.826
13
7.626
-0.592
0.592
0.592
15
-6.590
-2.428
0.444
-0.889
17
5.795
-1.291
0.346
0.346
19
-5.165
1.034
0.277
0.277
21
4.654
1.239
0.227
-0.454
23
-4.230
0.189
0.189
0.189
25
3.872
0.160
0.160
0.160
27
-3.565
0.750
0.137
-0.274
29
3.300
0.444
0.119
0.119
31
-3.068
-0.388
0.104
0.104
33
2.862
-0.502
0.092
-0.184
35
-2.679
-0.082
0.082
0.082
37
2.515
-0.073
0.073
0.073
39
-2.368
-0.359
0.066
-0.131
41
2.230
-0.222
0.060
0.060
7.6.10 Other ACI Specifications
Settling Time:
to within 10% of accuracy:
0.08s
Maximum Terminal
0 - 3.2mA :
50
µ
H
Inductance:
3.2mA - 320mA :
30
µ
H
320mA - 3.2A
:
18
µ
H
3.2A - 10.5A :
5.5
µ
H
10.5A - 20A
:
2.5
µ
H
(With 10 turn or 50 turn output selected):
3.2A - 1000A :
700
µ
H
NOTES: [1]
Tcal = temperature at calibration. Factory calibration temperature = 23
°
C.
[2]
Frequency Accuracy: 25ppm of output frequency.