Section 7: Model 9100: Specifications
7-7
Final Width = 215mm
7.4.10 Other ACV Specifications
Settling Time (to within 10% of accuracy):
≤
105V: 0.08s;
>105V: 0.5s.
Load Regulation:
For loads <|1M
Ω
|
≤
105V, add: [(200/R
LOAD
) + (C
LOAD
* x F
2
x 0.03)] % of output
For loads <|1M
Ω
| >105V, add: [(200/R
LOAD
) + (C
LOAD
* x F
2
x 0.19 + C
LOAD
*
• 3E7)] % of output
*
= To calculate C
LOAD
limit from Current compliance specification, while using 9105 lead set, allow
≈
30pF for lead set.
Maximum Capacitance:
1000pF; subject to Output Current Limitations at HF.
7.4.9
Waveshape Harmonic Analysis
(Peak values as a percentage of the Fundamental's Peak Value)
Harmonic
Square
Impulse
Triangular
Trapezoidal
1
100.00
100.00
100.00
100.00
3
-33.32
60.71
11.11
-22.22
5
19.98
14.93
4.000
4.000
7
-14.25
-7.616
2.041
2.041
9
11.07
-6.746
1.235
-2.469
11
-9.040
-0.826
0.826
0.826
13
7.626
-0.592
0.592
0.592
15
-6.590
-2.428
0.444
-0.889
17
5.795
-1.291
0.346
0.346
19
-5.165
1.034
0.277
0.277
21
4.654
1.239
0.227
-0.454
23
-4.230
0.189
0.189
0.189
25
3.872
0.160
0.160
0.160
27
-3.565
0.750
0.137
-0.274
29
3.300
0.444
0.119
0.119
31
-3.068
-0.388
0.104
0.104
33
2.862
-0.502
0.092
-0.184
35
-2.679
-0.082
0.082
0.082
37
2.515
-0.073
0.073
0.073
39
-2.368
-0.359
0.066
-0.131
41
2.230
-0.222
0.060
0.060
7.4.8
AC Voltage Accuracy (Trapezoidal-Wave)
Frequency
Output Voltage Span
Accuracy *
Current
Band
[2]
RMS
Peak
±
(% Floor)
Compliance
(Hz)
1 Year — Tcal
[1]
±
5
°
C
10 - 1k
0V - 12.56mV
0V - 14.14mV
0.12 + 450
µ
V
20mA
10 - 1k
12.56mV - 40.19mV 14.14mV - 45.25mV
0.12 + 150
µ
V
20mA
10 - 1k
40.19mV - 402mV
45.25mV - 452.5mV
0.12 + 40
µ
V
20mA
10 - 1k
402mV - 4.02V
452.5mV - 4.525V
0.12 + 400
µ
V
20mA
10 - 1k
4.02V - 40.2V
4.525V - 45.25V
0.12 + 4mV
20mA
10 - 1k
40.2V - 131.9V
45.25V - 148.4V
0.12 + 10mV
20mA
45 - 65
131.9V - 402V
148.4V - 452.5V
0.15 + 40mV
6mA
45 - 65
402V - 500V
452.5V - 566V
0.15 + 110mV
6mA
Ratios and Factors based on
Trapezoidal-Wave Unit-Value Peak
Peak:
1.0000
Peak to Peak:
2.0000
RMS:
0.8819
Mean:
0.8333
Crest Factor:
1.3390
Form Factor:
1.0583
∗
=
For loads < |1M
Ω
|: add load regulation error.