Chapter 10 Troubleshooting
PAGE 10-8
•
Code A04-05 - SYSTEM MEMORY ERROR / STORED DATA READ ERROR
An error occured during a READ attempt from SDRAM saved data.
CAUSE:
1. If the controller is located in an electric or magnetic noise field.
2. SDRAM chip has malfunctioned.
RECOVERY:
1. Verify that the controller is not located near any high voltage transient power sources. Relocate
as required and reinitialize the system.
2. Turn control power off to the unit for at least 5 seconds then re-apply power.
3. Replace controller.
•
Code A04-06 - SYSTEM MEMORY ERROR / RTC WRITE ERROR
An error occurred during a WRITE attempt to the Real-time Clock chip.
CAUSE:
1. If the controller is located in an electric or magnetic noise field.
2. RTC chip has malfunctioned.
RECOVERY:
1. Verify that the controller is not located near any high voltage transient power sources. Relocate
as required and reinitialize the system.
2. Turn control power off to the unit for at least 5 seconds then re-apply power.
3. Replace controller.
•
Code A04-07 - SYSTEM MEMORY ERROR / RTC READ ERROR
An error occurred during a READ attempt from the Real-time Clock chip.
CAUSE:
1. If the controller is located in an electric or magnetic noise field.
2. RTC chip has malfunctioned.
RECOVERY:
1. Verify that the controller is not located near any high voltage transient power sources. Relocate
as required and reinitialize the system.
2. Turn control power off to the unit for at least 5 seconds then re-apply power.
3. Replace controller.
Summary of Contents for AFC3000
Page 1: ...AFC3000E HW 1 ...
Page 17: ......
Page 18: ...Chapter 1 Outline PAGE 1 1 Chapter 1 Outline 1 ...
Page 25: ......
Page 26: ...Chapter 2 Specifications PAGE 2 1 Chapter 2 Specifications 2 ...
Page 34: ...Chapter 3 System Description PAGE 3 1 Chapter 3 System Description 3 ...
Page 64: ...Chapter 4 Installation and Wiring PAGE 4 1 Chapter 4 Installation and Wiring 4 ...
Page 131: ...Chapter 4 Installation and Wiring PAGE 4 68 Blank Page ...
Page 132: ...Chapter 5 I O Expansion Unit Page 5 1 Chapter 5 I O Expansion Unit 5 ...
Page 164: ...Chapter 6 Power up and Initial Checks PAGE 6 1 Chapter 6 Power Up and Initial Checks 6 ...
Page 168: ...Chapter 7 Fastening Instructions PAGE 7 1 Chapter 7 Fastening Instructions 7 ...
Page 207: ... Blank Page ...
Page 208: ...Chapter 8 System Operation PAGE 8 1 Chapter 8 System Operation 8 ...
Page 259: ...Chapter 8 System Operation PAGE 8 52 ...
Page 260: ...Chapter 9 Maintenance Inspection PAGE 9 1 Chapter 9 Maintenance Inspection 9 ...
Page 268: ...Chapter 10 Troubleshooting PAGE 10 1 Chapter 10 Troubleshooting 10 ...
Page 294: ......