Chapter 4 Installation and Wiring
PAGE 4-31
4-6-3 PLC IO Signal (Multi System
:
:
:
:
Master OUTDATA Signal)
IN: Input Signal
OUT: Output Signal
NC: Normal Close NO: Normal Open
BANK
No.13
Pin
No.
OUT DATA
Signal Name
Function
・
・
・
・
Usage Instruction
OFF
15
OUT DATA 0
TOTAL REJECT
Output when the fastening result of any of the connected spindles is a
REJECT. Indicates that the fastening operation has fallen outside of the
programmed fastening limits.
16
OUT DATA 1
TOTAL ACCEPT
Output when the fastening results of all connected spindles is a ACCEPT.
Indicates the fastening operation is within the programmed fastening
limits.
17
OUT DATA 2
TOTAL ABNORMAL
Output when an Abnormal condition occurs in any of the connected
spindles. This signal indicates that the System has detected an internal
fault, and can no longer proceed.
18
OUT DATA 3
TOTAL READY
Output when the all of the connected spindles are in the READY
condition.
19
OUT DATA 4
TOTAL BUSY
Output after a START signal is received and active until the fastening
cycle is complete and the READY signal is output.
20
OUT DATA 5
SEQ SELECT BIT 0
Output confirmation of SEQUENCE SELECT 0~4 input selections.
Sequence bits are active according to what sequence is set from the
sequence select inputs. Used to confirm proper sequence before
fastening starts.
21
OUT DATA 6
SEQ SELECT BIT 1
22
OUT DATA 7
SEQ SELECT BIT 2
23
OUT DATA 8
SEQ SELECT BIT 3
24
OUT DATA 9
SEQ SELECT BIT 4
25
OUT DATA 10 DATA AVAILABLE
Output when the fastening result data is available.
26
OUT DATA 11 SPINDLE IN BYPASS
Output when any connected spindle is in Bypass
ON
15
OUT DATA 0
REJECT(NG) (Spdl. only)
Output when the fastening result of the Master spindle is a REJECT.
16
OUT DATA 1
ACCEPT(OK) (Spdl. only)
Output when the press results of the Master spindle are an ACCEPT.
17
OUT DATA 2
ABNORMAL (Spdl. only)
Output when an Abnormal condition on the Master spindle occurs. This
signal indicates that the spindle has detected an internal fault and can no
longer proceed.
18
OUT DATA 3
READY (Spdl. only)
Indicates the Master spindle is ready to operate and inputs are enabled.
19
OUT DATA 4
BUSY (Spdl. only)
Output after a START signal is received from the Master spindle and
active until the fastening cycle is complete and the READY signal is
output.
20
OUT DATA 5
PAR SEL. BIT 0(Spdl only)
Output confirmation of the Master spindle PARAMETER SELECT 0~4
selections.
21
OUT DATA 6
PAR SEL. BIT 1(Spdl only)
22
OUT DATA 7
PAR SEL. BIT 2(Spdl only)
23
OUT DATA 8
PAR SEL. BIT 3(Spdl only)
24
OUT DATA 9
PAR SEL. BIT 4(Spdl only)
25
OUTDATA 10 -
Not used
26
OUT DATA 11 BYPASS (Spdl only)
Output when the Master spindle is bypassed either from bypass input
signals or from the controller’s bypass switch.
Summary of Contents for AFC3000
Page 1: ...AFC3000E HW 1 ...
Page 17: ......
Page 18: ...Chapter 1 Outline PAGE 1 1 Chapter 1 Outline 1 ...
Page 25: ......
Page 26: ...Chapter 2 Specifications PAGE 2 1 Chapter 2 Specifications 2 ...
Page 34: ...Chapter 3 System Description PAGE 3 1 Chapter 3 System Description 3 ...
Page 64: ...Chapter 4 Installation and Wiring PAGE 4 1 Chapter 4 Installation and Wiring 4 ...
Page 131: ...Chapter 4 Installation and Wiring PAGE 4 68 Blank Page ...
Page 132: ...Chapter 5 I O Expansion Unit Page 5 1 Chapter 5 I O Expansion Unit 5 ...
Page 164: ...Chapter 6 Power up and Initial Checks PAGE 6 1 Chapter 6 Power Up and Initial Checks 6 ...
Page 168: ...Chapter 7 Fastening Instructions PAGE 7 1 Chapter 7 Fastening Instructions 7 ...
Page 207: ... Blank Page ...
Page 208: ...Chapter 8 System Operation PAGE 8 1 Chapter 8 System Operation 8 ...
Page 259: ...Chapter 8 System Operation PAGE 8 52 ...
Page 260: ...Chapter 9 Maintenance Inspection PAGE 9 1 Chapter 9 Maintenance Inspection 9 ...
Page 268: ...Chapter 10 Troubleshooting PAGE 10 1 Chapter 10 Troubleshooting 10 ...
Page 294: ......