[System Parameters – continued]
D-No. 010 Controller maximum current
Cannot be changed.
This indicates the maximum current value of the controller
D-No. 011 IP Address (upper 6 digits)
D-No. 012 IP Address (lower 6 digits)
Setting range: 0 to 255
The IP address for the controller Ethernet port is set here. In a MULTI system, the Ethernet port for the
MASTER spindle is only used. (Slave spindles will still display IP addresses, but are not used)
* D-Nos. 011 to 016 become available upon rebooting the control power after being changed.
D-No. 013 Subnet Mask (upper 6 digits)
D-No. 014 Subnet Mask (lower 6 digits)
Setting range: 0 to 255
The subnet mask is set here.
* D-Nos. 011 to 016 become available upon rebooting the control power after being changed.
D-No. 015 Default Gateway (upper 6 digits)
Setting range: 0 to 255
D-No. 016 Default Gateway (lower 6 digits)
Setting range: 0 to 255
The default gateway is set here.
* D-Nos. 011 to 016 become available upon rebooting the control power after being changed.
D-No. 017 MAC Address (upper 6 digits) Cannot be changed.
D-No. 018 MAC Address (lower 6 digits) Cannot be changed.
The MAC ID address of the Ethernet port is indicated.
D-No. 019 RTC: Year/Month/Day
Setting range: 13 to 99 (year), 1 to 12 (month), 1 to 31 (day)
D-No. 020 RTC: Time
Setting range: 0 to 23 (hours), 0 to 59 (minutes), 0 to 59 (seconds)
The date and time of the real time clock (RTC) are indicated. The range for the year is 2013 to 2099.
* This is not indicated at a SLAVE spindle in a MULTI system.
D-No. 021 Erase Fastening Result History/Format CF Card
Erasing of the fastening results history can be executed. Please refer to “Copying of Parameters and
Erasing of the Fastening Result History” in Section 8-6 regarding the method for erasing the fastening
results history.
Also, if the Expansion Unit 2 (Model: MFC-CF) is installed, formatting of the CF card can be executed.
Please refer to “Formatting the Memory Card” regarding the method for formatting the CF card.
D-No. 022 Parameter Copy
Copying of parameters is performed. Please refer to “Copying of Parameters and Erasing of the
Fastening Result History” on Section 8-6 regarding the method for copying parameters.
D-No. 023 For in-house adjustment
Not used.
D-No. 024 FPGA Version of controller
This indicates the FPGA (Field Programmable Gate Array) version number of controller.
D-No. 025 FPGA version of MFC-CF module
This indicates the FPGA (Field Programmable Gate Array) version number of MFC-CF module.
Summary of Contents for AFC3000
Page 1: ...AFC3000E HW 1 ...
Page 17: ......
Page 18: ...Chapter 1 Outline PAGE 1 1 Chapter 1 Outline 1 ...
Page 25: ......
Page 26: ...Chapter 2 Specifications PAGE 2 1 Chapter 2 Specifications 2 ...
Page 34: ...Chapter 3 System Description PAGE 3 1 Chapter 3 System Description 3 ...
Page 64: ...Chapter 4 Installation and Wiring PAGE 4 1 Chapter 4 Installation and Wiring 4 ...
Page 131: ...Chapter 4 Installation and Wiring PAGE 4 68 Blank Page ...
Page 132: ...Chapter 5 I O Expansion Unit Page 5 1 Chapter 5 I O Expansion Unit 5 ...
Page 164: ...Chapter 6 Power up and Initial Checks PAGE 6 1 Chapter 6 Power Up and Initial Checks 6 ...
Page 168: ...Chapter 7 Fastening Instructions PAGE 7 1 Chapter 7 Fastening Instructions 7 ...
Page 207: ... Blank Page ...
Page 208: ...Chapter 8 System Operation PAGE 8 1 Chapter 8 System Operation 8 ...
Page 259: ...Chapter 8 System Operation PAGE 8 52 ...
Page 260: ...Chapter 9 Maintenance Inspection PAGE 9 1 Chapter 9 Maintenance Inspection 9 ...
Page 268: ...Chapter 10 Troubleshooting PAGE 10 1 Chapter 10 Troubleshooting 10 ...
Page 294: ......