Chapter 10 Troubleshooting
PAGE 10-9
10-5 Servo Amplifier Reply Errors [A.05 - *]
•
Code A05-01 - SERVO AMPLIFIER REPLY ERROR / NO REPLY FROM RESOLVER
The controller is attempting to turn the motor but is not receiving any signals back from the resolver
to indicate that the tool is actually turning or the speed reference on the amplifier is not responding.
CAUSE:
1. The tool cable is damaged or not connected.
2. When the resolver, motor or the controller malfunctions.
3. If there is excessive binding in the fastener, transmission or the spindle assembly keeping the
motor from turning.
4. System Parameter #523 (Fastening Current Limit) is not set to the correct value (may be too low).
5. Torque Transducer damage/error will not allow motor to start/turn.
RECOVERY:
1. Verify that the tool cable is securely connected at both ends and free from cuts, abrasive wear or
kinks
2. Connect a known good spare tool cable to the existing tool.
3. Exchange tool and/or controller with known working units. Reinitialize the system after
exchanges.
4. Verify that System Parameter #523 [Fastening Current Limit] is set to the correct default value. (A
lower value than the default value will limit the current output of the controller to the value
programmed)
5. Inspect and correct any binding in the spindle assembly, transmission or fasteners.
Summary of Contents for AFC3000
Page 1: ...AFC3000E HW 1 ...
Page 17: ......
Page 18: ...Chapter 1 Outline PAGE 1 1 Chapter 1 Outline 1 ...
Page 25: ......
Page 26: ...Chapter 2 Specifications PAGE 2 1 Chapter 2 Specifications 2 ...
Page 34: ...Chapter 3 System Description PAGE 3 1 Chapter 3 System Description 3 ...
Page 64: ...Chapter 4 Installation and Wiring PAGE 4 1 Chapter 4 Installation and Wiring 4 ...
Page 131: ...Chapter 4 Installation and Wiring PAGE 4 68 Blank Page ...
Page 132: ...Chapter 5 I O Expansion Unit Page 5 1 Chapter 5 I O Expansion Unit 5 ...
Page 164: ...Chapter 6 Power up and Initial Checks PAGE 6 1 Chapter 6 Power Up and Initial Checks 6 ...
Page 168: ...Chapter 7 Fastening Instructions PAGE 7 1 Chapter 7 Fastening Instructions 7 ...
Page 207: ... Blank Page ...
Page 208: ...Chapter 8 System Operation PAGE 8 1 Chapter 8 System Operation 8 ...
Page 259: ...Chapter 8 System Operation PAGE 8 52 ...
Page 260: ...Chapter 9 Maintenance Inspection PAGE 9 1 Chapter 9 Maintenance Inspection 9 ...
Page 268: ...Chapter 10 Troubleshooting PAGE 10 1 Chapter 10 Troubleshooting 10 ...
Page 294: ......