![FEC AFC3000 Hardware Operation Manual Download Page 254](http://html.mh-extra.com/html/fec/afc3000/afc3000_hardware-operation-manual_547828254.webp)
Chapter 8 System Operation
PAGE 8- 47
8-7-6 Fastening Parameters (Rate / Time)
D-No.300
1
ST
Rate Low Limit
[Nm/deg]
Setting Range
:
Tool’s minimum torque rate
~
tool’s maximum torque rate
Set the low limit for the slope of torque and angle measured between two points from D-No.112 [1
ST
Rate
Start Torque] to D-No.113 [1
ST
Rate End Torque].
Judgment is conducted at the point when the D-No.113 [1
ST
Rate End Torque] is reached.
D-No.301
1
ST
Rate High Limit
[Nm/deg]
Setting Range
:
Tool’s minimum torque rate
~
tool’s maximum torque rate
Set the high limit for the slope of torque and angle measured between two points from D-No.112 [1
ST
Rate Start Torque] to D-No.113 [1
ST
Rate End Torque].
Judgment is conducted at the point when the D-No.113 [1
ST
Rate End Torque] is reached.
D-No.302
2
ND
Rate Low Limit
[Nm/deg]
Setting Range: Tool’s minimum torque rate
~
tool’s maximum torque rate
Set the low limit for the slope of torque and angle measured between two points from D-No.114 [2
ND
Rate
Start Torque] to D-No.115 [2
ND
Rate End Torque].
Judgment is conducted at the point when the D-No.115 [2
ND
Rate End Torque] is reached.
D-No.303
2
ND
Rate High Limit
[Nm/deg]
Setting Range
:
Tool’s minimum torque rate
~
tool’s maximum torque rate
Set the high limit for the slope of torque and angle measured between two points from D-No.114 [2
ND
Rate Start Torque] to D-No.115 [2
ND
Rate End Torque].
Judgment is conducted at the point when the D-No.115 [2
ND
Rate End Torque] is reached.
D-No.304
3
RD
Rate Low Limit
[Nm/deg]
Setting Range
:
Tool’s minimum torque rate
~
tool’s maximum torque rate
Set the low limit for the slope of torque and angle measured between two points from D-No.116 [3
RD
Rate
Start Torque] to D-No.117 [3
RD
Rate End Torque].
Judgment is conducted at the point when the D-No.117 [3
RD
Rate End Torque] is reached.
D-No.305
3
RD
Rate High Limit
[Nm/deg]
Setting Range
:
Tool’s minimum torque rate
~
tool’s maximum torque rate
Set the high limit for the slope of torque and angle measured between two points from D-No.116 [3
RD
Rate Start Torque] to D-No.117 [3
RD
Rate End Torque].
Judgment is conducted at the point when the D-No.117 [3
RD
Rate End Torque] is reached.
・・・・
The minimum (maximum) torque rate of a tool differs according to the tool model.
Please refer to “Tool Models” on Section 2-2-3 regarding the allowed input range.
Caution
Summary of Contents for AFC3000
Page 1: ...AFC3000E HW 1 ...
Page 17: ......
Page 18: ...Chapter 1 Outline PAGE 1 1 Chapter 1 Outline 1 ...
Page 25: ......
Page 26: ...Chapter 2 Specifications PAGE 2 1 Chapter 2 Specifications 2 ...
Page 34: ...Chapter 3 System Description PAGE 3 1 Chapter 3 System Description 3 ...
Page 64: ...Chapter 4 Installation and Wiring PAGE 4 1 Chapter 4 Installation and Wiring 4 ...
Page 131: ...Chapter 4 Installation and Wiring PAGE 4 68 Blank Page ...
Page 132: ...Chapter 5 I O Expansion Unit Page 5 1 Chapter 5 I O Expansion Unit 5 ...
Page 164: ...Chapter 6 Power up and Initial Checks PAGE 6 1 Chapter 6 Power Up and Initial Checks 6 ...
Page 168: ...Chapter 7 Fastening Instructions PAGE 7 1 Chapter 7 Fastening Instructions 7 ...
Page 207: ... Blank Page ...
Page 208: ...Chapter 8 System Operation PAGE 8 1 Chapter 8 System Operation 8 ...
Page 259: ...Chapter 8 System Operation PAGE 8 52 ...
Page 260: ...Chapter 9 Maintenance Inspection PAGE 9 1 Chapter 9 Maintenance Inspection 9 ...
Page 268: ...Chapter 10 Troubleshooting PAGE 10 1 Chapter 10 Troubleshooting 10 ...
Page 294: ......