![FEC AFC3000 Hardware Operation Manual Download Page 30](http://html.mh-extra.com/html/fec/afc3000/afc3000_hardware-operation-manual_547828030.webp)
Chapter 2 Specifications
PAGE 2-5
【
【
【
【
Warning - Static Electricity
】
】
】
】
・
・
・
・
Due to the usage of many electronic parts be careful not to expose the controller to
static electricity.
Keep in mind to discharge static electricity from the body by touching something
metal before touching an operation switch on the front panel.
2-1-4 Duty Cycle Calculation
Duty cycle is the ratio of tool fastening (running) time and idle time.
The duty cycle for AFC3000 Nutrunner System is calculated as below.
Duty Cycle
(%)=
(%)=
(%)=
(%)=
Fastening Time ÷
(
(
(
(
Fastening Time
+
+
+
+
Idle Time
)
)
)
)
× 100
Maintain the duty cycle less than 60% under normal conditions.
An abnormal (A8-10 “Overload Error”) may occur if the unit is used in a condition that the duty cycle is
over 60%. (Additional abnormals may also be caused by high duty due to the higher current and heat
generated when the motor is ‘overworked’. (Make sure the motor surface temperature does not exceed
70°C (158°F) (Outer Motor Case)). Contact FEC regarding a specified cycle time more than 60% Duty.
2-2 Unit Identification
2-2-1 MFC Unit Type
Unit Type
Name
Description
Part No.
Controller
AFC3000 24A Controller
For Tool Type CFT-***RS1-*
MFC-S024
AFC3000 60A Controller
For Tool Type CFT-***RS3-*
MFC-S060
AFC3000 120A Controller
For RM4, RM5 Motors
MFC-S120
Expansion
Unit
AFC3000-D-I/O
Expansion Unit 1 with discrete I/O
MFC-DT
AFC3000-FIELDBUS
Expansion Unit 1 with no Fieldbus
*1
MFC-FB
AFC3000-CCLink-V2
Expansion Unit 1 with CC-Link V2
MFC-CC
AFC3000-DEVICENET
Expansion Unit 1 with DeviceNet
MFC-DN
AFC3000-PROFIBUSDP-V1 Expansion Unit 1 with Profibus
MFC-PB
AFC3000-EtherNet-I/P
Expansion Unit 1 with Ethernet-I/P I/O MFC-EN
AFC3000-PROFINET
Expansion Unit 1 with Profinet I/O
MFC-PN
AFC3000-EtherCat
Expansion Unit 1 with EtherCat I/O
MFC-EC
AFC3000-CF Expansion
Expansion Unit 2 with CompactFlash
Expansion RS232C Connector
MFC-CF
*1
:
Anybus-CompactCom module is NOT installed. (Requires Fieldbus specific board to operate)
*Anybus® is a registered trade mark of HMS Industrial Networks in Sweden, USA, and other countries.
Summary of Contents for AFC3000
Page 1: ...AFC3000E HW 1 ...
Page 17: ......
Page 18: ...Chapter 1 Outline PAGE 1 1 Chapter 1 Outline 1 ...
Page 25: ......
Page 26: ...Chapter 2 Specifications PAGE 2 1 Chapter 2 Specifications 2 ...
Page 34: ...Chapter 3 System Description PAGE 3 1 Chapter 3 System Description 3 ...
Page 64: ...Chapter 4 Installation and Wiring PAGE 4 1 Chapter 4 Installation and Wiring 4 ...
Page 131: ...Chapter 4 Installation and Wiring PAGE 4 68 Blank Page ...
Page 132: ...Chapter 5 I O Expansion Unit Page 5 1 Chapter 5 I O Expansion Unit 5 ...
Page 164: ...Chapter 6 Power up and Initial Checks PAGE 6 1 Chapter 6 Power Up and Initial Checks 6 ...
Page 168: ...Chapter 7 Fastening Instructions PAGE 7 1 Chapter 7 Fastening Instructions 7 ...
Page 207: ... Blank Page ...
Page 208: ...Chapter 8 System Operation PAGE 8 1 Chapter 8 System Operation 8 ...
Page 259: ...Chapter 8 System Operation PAGE 8 52 ...
Page 260: ...Chapter 9 Maintenance Inspection PAGE 9 1 Chapter 9 Maintenance Inspection 9 ...
Page 268: ...Chapter 10 Troubleshooting PAGE 10 1 Chapter 10 Troubleshooting 10 ...
Page 294: ......