Chapter 8 System Operation
PAGE 8- 21
System Parameter Setting Method
Parameter displayed with [SYS] in the PAR No. display is a System Parameter.
Press the [SET] push-button after editing the parameter. Once the SET push-button has been pressed
the [DATA] display will show
“
CHAnGE
”
and “
no
” will appear on the “D-NO” display. “
yES
” or “
no
” can
be selected by pressing the [
▲
] and [
▼
] buttons. If “
yES
” is selected, confirm the entered data by
pressing the [SET] button. The [SET] and [MODE] buttons will have no effect when “
no
” appears.
*If neither YES or NO is selected within 2 seconds, the new data will be ignored and the system will exit
the “Data Edit Mode”.
・
・
・
・
The changed value will be saved into the internal memory at the moment the
RUN/BYPASS switch is changed from BYPASS to RUN or when the BYPASS
signal turns from ON to OFF.
・
・
・
・
If the power is turned off when changing the set value in BYPASS mode, the
changed value will be canceled and will be set back to the original value.
・
・
・
・
Some of the system parameters (PAR No.000) are not changed, until the control
power is rebooted. (D-No.003 Function Version, D-No.011
~
~
~
~
016 TCP/IP Setting
etc.)
・
・
・
・
When the Controller Tool No. (PAR No. “SYS,” D-No. “200”) is changed, the
fastening parameter set values are subject to initialization and automatic
correction.
・・・・
Initialization
・・・
・・・
・・・
・・・
The calibration torque, rate 1 - 3 high and low limits, full scale
current, high current limit, and the current limit are subject to initialization.
・・・・
Automatic Correction
・・・
・・・
・・・
・・・
If the torque, speed, or current low limit set value falls
outside the high or low limit value of the tool of the tool No. for which the set
value was changed, this set value is subject to automatic correction.
System
Parameter
Change
▲
or
▼
◎
SET
◎
SET
Within 2 seconds
Within 2 seconds
Summary of Contents for AFC3000
Page 1: ...AFC3000E HW 1 ...
Page 17: ......
Page 18: ...Chapter 1 Outline PAGE 1 1 Chapter 1 Outline 1 ...
Page 25: ......
Page 26: ...Chapter 2 Specifications PAGE 2 1 Chapter 2 Specifications 2 ...
Page 34: ...Chapter 3 System Description PAGE 3 1 Chapter 3 System Description 3 ...
Page 64: ...Chapter 4 Installation and Wiring PAGE 4 1 Chapter 4 Installation and Wiring 4 ...
Page 131: ...Chapter 4 Installation and Wiring PAGE 4 68 Blank Page ...
Page 132: ...Chapter 5 I O Expansion Unit Page 5 1 Chapter 5 I O Expansion Unit 5 ...
Page 164: ...Chapter 6 Power up and Initial Checks PAGE 6 1 Chapter 6 Power Up and Initial Checks 6 ...
Page 168: ...Chapter 7 Fastening Instructions PAGE 7 1 Chapter 7 Fastening Instructions 7 ...
Page 207: ... Blank Page ...
Page 208: ...Chapter 8 System Operation PAGE 8 1 Chapter 8 System Operation 8 ...
Page 259: ...Chapter 8 System Operation PAGE 8 52 ...
Page 260: ...Chapter 9 Maintenance Inspection PAGE 9 1 Chapter 9 Maintenance Inspection 9 ...
Page 268: ...Chapter 10 Troubleshooting PAGE 10 1 Chapter 10 Troubleshooting 10 ...
Page 294: ......