![FEC AFC3000 Hardware Operation Manual Download Page 104](http://html.mh-extra.com/html/fec/afc3000/afc3000_hardware-operation-manual_547828104.webp)
Chapter 4 Installation and Wiring
PAGE 4-41
4-7 External Monitoring Interface
4-7-1 Output Signal Specifications
This auxiliary connector (Located under top cover access plate) is used to output Torque, Angle, Current
& Speed signals to external equipment for monitoring purposes (X-Y Plotter, etc). The signals output from
this connector are the same signals that the system receives during the fastening process. This
connection is not required for the system to operate.
Pin No.
Signal
IN/OUT
Description
1
EA2
OUT
Disabled
2
EB2
OUT
Disabled
3
ANGLE PULSE
OUT
Angle Pulse monitor output
4
ANGLE CW/CCW
OUT
Angle direction output
5
GND
Monitoring signal output GND
6
TD2
OUT
Disabled
7
MON1
OUT
Current Monitor output (10V = max. current)
8
MON2
OUT
Speed monitor output (10V = max rotation speed)
9
TD1
OUT
Analog torque output
TORQUE OUT
:
:
:
:
Torque Voltage
(
Analog Voltage
)
Monitoring voltage is indicated from zero torque to full scale torque and the potential difference is
3.7V. The zero voltage is the voltage when the tool is unloaded (nothing connected to the output
shaft and no torque applied).
※
The zero voltage is not 0V.
(
Origin voltage range: -0.4V
~
+0.4V
)
Also the zero voltage of each tool may vary even for the same type of tool.
(Ex: If the zero voltage is -0.3V and the voltage at full scale torque is +3.4V, the voltage change is
⊿
3.7V.)
ANGLE PULSE
:
:
:
:
Angle Pulse Signal
(
5V TTL Signal
)
Angle pulse will output one pulse for one degree of rotation (tool output square) if DIP SW1-4 is set
as default (OFF). (See 4-12-2 for DIP SW setting)
※
This may differ from the actual rotation angle
(The range of pulses when rotating the end of the tool once is 358
~
362pulses.)
ANGLE CW/CCW
:
:
:
:
Forward/Reverse Signal
(
5V TTL Signal
)
Outputs “HI” when the motor rotates in a clockwise direction and “LOW” when the motor rotates in a
counter-clockwise direction.
【
【
【
【
Compatible Connector
】
】
】
】
Model No.
:
HDEB-9P D-SUB9 pin Male, with solder type
HDE-CTF(50) Connector case, screw size M2.6
Angle Pulse Signal
1deg
Forward/Reverse Signal
CCW
Tool Rotation
CW
Stop
Summary of Contents for AFC3000
Page 1: ...AFC3000E HW 1 ...
Page 17: ......
Page 18: ...Chapter 1 Outline PAGE 1 1 Chapter 1 Outline 1 ...
Page 25: ......
Page 26: ...Chapter 2 Specifications PAGE 2 1 Chapter 2 Specifications 2 ...
Page 34: ...Chapter 3 System Description PAGE 3 1 Chapter 3 System Description 3 ...
Page 64: ...Chapter 4 Installation and Wiring PAGE 4 1 Chapter 4 Installation and Wiring 4 ...
Page 131: ...Chapter 4 Installation and Wiring PAGE 4 68 Blank Page ...
Page 132: ...Chapter 5 I O Expansion Unit Page 5 1 Chapter 5 I O Expansion Unit 5 ...
Page 164: ...Chapter 6 Power up and Initial Checks PAGE 6 1 Chapter 6 Power Up and Initial Checks 6 ...
Page 168: ...Chapter 7 Fastening Instructions PAGE 7 1 Chapter 7 Fastening Instructions 7 ...
Page 207: ... Blank Page ...
Page 208: ...Chapter 8 System Operation PAGE 8 1 Chapter 8 System Operation 8 ...
Page 259: ...Chapter 8 System Operation PAGE 8 52 ...
Page 260: ...Chapter 9 Maintenance Inspection PAGE 9 1 Chapter 9 Maintenance Inspection 9 ...
Page 268: ...Chapter 10 Troubleshooting PAGE 10 1 Chapter 10 Troubleshooting 10 ...
Page 294: ......