328
ExtremeWare XOS 11.0 Command Reference Guide
Commands for Status Monitoring and Statistics
configure log target severity
configure log target [console | memory-buffer | nvram | primary-msm |
backup-msm | session | syslog [<all | ipaddress> {vr <vr_name>} [local0 ...
local7]]] {severity <severity> {only}}
Description
Sets the severity level of messages sent to the target.
Syntax Description
Default
By default, targets are sent messages of the following severity level and above:
•
console display—info
•
memory buffer—debug-data
•
NVRAM—warning
•
session—info
•
syslog—debug-data
•
primary MSM—error
•
backup MSM—error
If a virtual router is not specified, VR-Mgmt is used.
Usage Guidelines
This command configures the specified target with a severity level. The filter associated with the target
is not affected. A message is sent to a target if the target has been enabled, the message passes the
associated filter, the message is at least as severe as the configured severity level, and the message
output matches the regular expression specified.
See the command
show log
on page 364 for a detailed description of severity levels.
console
Specifies the console display.
memory-buffer
Specifies the switch memory buffer.
nvram
Specifies the switch NVRAM.
primary-msm
Specifies the primary MSM.
backup-msm
Specifies the backup MSM.
session
Specifies the current session (including console display).
syslog
Specifies a syslog target.
all
Specifies all of the remote syslog servers.
ipaddress
Specifies the syslog IP address.
vr_name
Specifies the virtual router that can reach the server IP address.
local0 ... local7
Specifies the local syslog facility.
severity
Specifies the least severe level to send (if the keyword only is omitted).
only
Specifies that only the specified severity level is to be sent.
Summary of Contents for ExtremeWare XOS 11.0
Page 26: ...26 ExtremeWare XOS 11 0 Command Reference Guide Contents...
Page 176: ...176 ExtremeWare XOS 11 0 Command Reference Guide Commands for Managing the Switch...
Page 262: ...262 ExtremeWare XOS 11 0 Command Reference Guide VLAN Commands...
Page 280: ...280 ExtremeWare XOS 11 0 Command Reference Guide FDB Commands...
Page 492: ...492 ExtremeWare XOS 11 0 Command Reference Guide EAPS Commands...
Page 536: ...536 ExtremeWare XOS 11 0 Command Reference Guide STP Commands...
Page 580: ...580 ExtremeWare XOS 11 0 Command Reference Guide ESRP Commands...
Page 876: ...876 ExtremeWare XOS 11 0 Command Reference Guide BGP Commands...
Page 926: ...926 ExtremeWare XOS 11 0 Command Reference Guide IP Multicast Commands...