Summa Series Servodrive Product Manual
Appendix
Document Version: V1.01
(Dec, 2019)
© 2019 ESTUN Automation Co., Ltd. All right reserved.
12-16
No.
Index
Name
Range
Unit
Default
When Enabled
Pn181
3219
Frequency of Notch Filter 1
50 to 5000
Hz
5000
Immediately
-
Pn182
321A
Depth of Notch Filter 1
0 to 23
-
0
Immediately
-
Pn183
321B
Width of Notch Filter 1
0 to 15
-
2
Immediately
-
Pn184
321C
Frequency of Notch Filter 2
50 to 5000
Hz
5000
Immediately
-
Pn185
321D
Depth of Notch Filter 2
0 to 23
-
0
Immediately
-
Pn186
321E
Width of Notch Filter 2
0 to 15
-
2
Immediately
-
Pn187
321F
Frequency of Notch Filter 3
50 to 5000
Hz
5000
Immediately
-
Pn188
3220
Depth of Notch Filter 3
0 to 23
-
0
Immediately
-
Pn189
3221
Width of Notch Filter 3
0 to 15
-
2
Immediately
-
Pn200
322C
Pulse Numbers for PG
Frequency Division
16 to 16384
1 pulse
16384
After restart
This parameter is used for setting the orthogonal differential-pulse numbers output by the encoder when the
Motor runs one revolution.