Summa Series Servodrive Product Manual
Installation
Document Version: V1.01
(Dec, 2019)
© 2019 ESTUN Automation Co., Ltd. All right reserved.
2-3
Installing More than One Drive in a Control Cabinet
Provide enough space around the Drive when installing more than one Drive in a control cabinet, as is
shown in Figure 2-3.
Figure 2-3
Install more than one Drive in a control cabinet
1mm
≥
30mm
≥
50mm
≥
30mm
≥
50mm
NOTE
The ED3S Drivers can be mounted closely and the distance between
adjacent Drives is 1mm.